摘要
介绍了390H发电机电刷和滑环的运行特性;针对一次发电机滑环由于负极环火引起正负滑环间短路的事故及处理情况,提出了正常维护要注意的事项及其建议。
An introduction is being presented to the slip ring, while failures between positive and negative negative riilg fire troubles described, and subsequent items for normal maintenance are therefore proposed. operation characteristics of a 390H generator brush's slip ring at primary side of the generator caused by treatment method and result presented. Noticeable
出处
《发电设备》
2009年第3期219-222,共4页
Power Equipment
关键词
发电机
电刷滑环
运行特性
异常处理
generator
brush's slip ring
operation characteristic
abnormal treatment