摘要 目的本研究对150例疑诊冠心病患者双源CT冠脉图像进行回顾性分析,探讨图像质量的影响因素和改善措施。方法本研究包括接受双源CT冠脉检查的患者共150例,其中男98例,女52例,平均年龄58.3岁。冠脉图像评价共分为5级,Ⅰ级-Ⅲ级为合格诊断图像,Ⅳ、Ⅴ级为不合格图像。对于心率波动>10次/分患者采用小螺距扫描,造影剂注射速率4.5-5.5ml/s。结果150例患者均顺利完成检查,平均心率波动幅度9.3±7.1次/分(房颤1例除外)。150例中共计142例为合格图像,8例为不合格图像。8例图像中有5例(窦性心率不齐2例,室性早搏2例,心脏起搏二联律1例)经心电编辑后达到合格,其余3例(呼吸伪影2例,房颤1例)经后处理图像仍未达标。结论采用小螺距扫描可在一定程度降低心率不齐对双源CT冠脉图像的影响;熟练应用心电编辑及时相重建技术可有效提高图像的合格率。 Objective To investigate the influencing factors on image quality of dual source CT coronary angiography by retrospective analysis of the images of 150 patients with suspected coronary artery disease. Methods 150 cases of suspected coronary artery disease were included in this study(98 male, 52 female, mean age 58.3years). Coronary artery images could be classified as 5 grade, grade 1 to 3 was defined as qualified images and grade 4 and 5 was defined as non-qualified images. Low "pitch"± scanning technique was applied to patients with the fluctuation of heart rate more than 10 bpm. Results All of 150 cases undertook dual source CT coronary angiography smoothly, the average fluctuation of heart rate was 9.3 ± 7.1 bpm (1 case of atrial fibrillation was excluded). Qualified images were obtained in 142 cases and the other 8 cases were non-qualified. By ECG-editing and multiple-phase reconstruction technique, 3 of 8 cases of non-qualified images reached optimal level. Conclusion Low "pitch"± scanning technique could reduce the effect of irregular heart rate on image quality of dual source CT coronary angiography and application of ECG-editing and multiple-phase reconstruction technique skillfully would be an effective way to improve image quality.
出处 《中国CT和MRI杂志》 2009年第2期33-35,共3页 Chinese Journal of CT and MRI
关键词 冠状动脉疾病 双源CT coronary heart disease dual source computed tomography
  • 相关文献

参考文献4

  • 1关计添,徐小虎,耿义群,于晓军,程英,郭岳霖,吴仁华.心率变化对64层CT冠状动脉造影图像质量的影响[J].中国CT和MRI杂志,2008,6(2):37-39. 被引量:14
  • 2Hans Scheffel,Hatem Alkadhi,André Plass,Robert Vachenauer,Lotus Desbiolles,Oliver Gaemperli,Tiziano Schepis,Thomas Frauenfelder,Thomas Schertler,Lars Husmann,Jürg Grunenfelder,Michele Genoni,Philipp A. Kaufmann,Borut Marincek,Sebastian Leschka. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J] 2006,European Radiology(12):2739~2747
  • 3Thorsten R. C. Johnson,Konstantin Nikolaou,Bernd J. Wintersperger,Alexander W. Leber,Franz Ziegler,Carsten Rist,Sonja Buhmann,Andreas Knez,Maximilian F. Reiser,Christoph R. Becker. Dual-source CT cardiac imaging: initial experience[J] 2006,European Radiology(7):1409~1415
  • 4Thomas G. Flohr,Cynthia H. McCollough,Herbert Bruder,Martin Petersilka,Klaus Gruber,Christoph Sü?,Michael Grasruck,Karl Stierstorfer,Bernhard Krauss,Rainer Raupach,Andrew N. Primak,Axel Küttner,Stefan Achenbach,Christoph Becker,Andreas Kopp,Bernd M. Ohnesorge. First performance evaluation of a dual-source CT (DSCT) system[J] 2006,European Radiology(6):1405