期刊文献+

电感耦合等离子体质谱测定豆奶粉中镉两种消解方法的比较 被引量:6

Comparison between two digestion ICP-MS methods of detecting cadmium in soy milk powder
原文传递
导出
摘要 目的:分别用两种方法预处理豆奶粉后用ICP-MS对样品溶液中的镉进行测定,对两种方法进行比较。方法:样品分别经湿法消化和微波消化后定容到一定体积,然后直接用ICP-MS进行分析,用混和内标校正基体干扰和漂移。结果:两种前处理方法产生的结果精密度均优于3%,回收率介于95%-100%,且对标准参考物质的测定结果均符合证书值要求。结论:两种处理方法均有较好的精密度和准确度,测定结果之间并无显著性差异。 Objective:To compare the two digestion ICP - MS methods of detecting cadmium in soy milk powder. Methods: After wet digestion and microwave digestion respectively, the samples were determined directly by inductively coupled plasma mass spectrometry using mixed internal standard to correct matrix interference and signal drifting. Results:The RSD of two methods was less than 3.0% , recoveries 95.0% - 100% and the results of analyzing standard materiel were satisfactory. Conclusion: Two methods all have good precision and veracity and there is no obvious difference between the results from two methods.
出处 《中国卫生检验杂志》 CAS 2009年第4期784-785,共2页 Chinese Journal of Health Laboratory Technology
基金 广州市医学科研课题(2008-YB-224)
关键词 ICP-MS 豆奶粉 Inductively coupled plasma mass spectrometry Soy milk powder Cadmium