摘要 某商业中心地下汽车库采用了宽扁梁和平板柱多层预应力混凝土结构,在可利用的地下建筑空间内比普通混凝土结构多建了1层车库。其人防、消防等偶然荷载远大于正常使用荷载,使得预应力混凝土构件抗裂设计在这两种荷载下很难同时满足设计要求,以优先满足正常使用荷载,辅以普通钢筋增强构件的延性来满足偶然荷载下的设计要求。采用塑胶管、直线形布筋方式减小预应力摩擦损失。宽扁梁结构的梁柱节点予以加强,以保证楼面荷载的顺利传递。 Focus on a tower building in central business district, the structural plan arrangement of its underground parking is optimized. The flat-beam and flat-plate structures are applied. Parking space of more than a floor is obtained. Because accident loads, such as defending load and fire protecting load, is more larger than normal live loads, it is difficuh to satisfy the design requirement of the resist cracking in the prestressed concrete members simultaneously. It is suggested that the normal condition be priority and general steel be assisted to reinforced ductility of the members. Prestressed friction loss is controlled by embedding plastic pipes and using linear tendon shape in the super long structures. The joint of beam-column in the flat-beam structure is strengthened for load transferring.
出处 《建筑结构》 CSCD 北大核心 2009年第4期43-45,共3页 Building Structure
关键词 预应力混凝土 楼盖 宽扁梁 预应力摩擦损失 prestressed concrete floor structure flat-beam friction loss
  • 相关文献

参考文献5

二级参考文献5

  • 1郭靳时 ,尹新生 ,隋莉莉 .钢筋混凝土有边梁扁梁边节点受力性能试验研究[J].工业建筑,2005,35(10):76-78. 被引量:2
  • 2GB50011-2001.建筑抗震设计规范.[S].,..
  • 3GB50010-2002.混凝土结构设计规范.[S].,..
  • 4林同炎.预应力混凝土结构设计[M].北京:中国铁道出版社,1983..
  • 5陈肇元,罗家谦.钢筋混凝土梁在爆炸压力荷载下的动力反应[A].清华大学抗震抗爆工程研究室科学研究报告第四集[C],清华大学出版社,1986.