摘要
研究针灸刺激量、电针刺激量、电针刺激强度的定义域及相关影响因素,探讨电针刺激量量化方案。通过对电针标准化工作的回顾,总结了目前电针应用状况和临床对照研究中刺激量量化存在的问题,阐述了针灸刺激量的不同见解和理解误区,分析了针灸刺激量、电针刺激量、电针刺激强度的定义域及相关影响因素。经技术分析,推导出电针脉冲能量、电针刺激强度、电针刺激量的计算方法和计算公式。提出的电针刺激量量化的几种方案具有一定的可行性,可操作性强。
In order to study on the definition domain and their correlated influencing factors about the acupuncture and moxibustion stimulation quantity, electroacupuncture (EA) stimulation quality and intensity, and to probe into the project of quantification of EA stimulation quantity. The authors reviewed the standardization work of EA, summed up the current state of the application of EA and the problems in quantification of the stimulation quantity in clinically control studies, expounded the different opinions and misunderstanding in acupuncture and moxibustion stimulation quantity and analyzed the definition domain and associated factors about acupuncture and moxibustion stimulation quantity and EA stimulation quantity and intensity. After the technical analysis, the calculation methods and formulas of pulse energy, quantity and intensity of EA stimulation were derived. On this basis, several schemes for the quantification of EA stimulation quantity with a certain feasibility and strong maneuverability are proposed.
出处
《中国针灸》
CAS
CSCD
北大核心
2009年第5期417-420,共4页
Chinese Acupuncture & Moxibustion
基金
国家中医药管理局中医药标准化项目:ZYYS-20070010
上海市卫生局科研项目:2006J004A
关键词
电针
剂量效应关系
针灸
电刺激
电刺激方法
国家标准
Electroacupuncture
Dose Response Relat Acup Mox
Electric Stimulation
Electric Stimulation Therapy
State Standard