期刊文献+

热线法同时测松散煤体导热系数及热扩散率 被引量:21

Measurements of Thermal Conductivity and Diffusivity of Loose Coal Using a Hot-Wire Method
原文传递
导出
摘要 针对目前尚无理想的松散煤体热物性综合测试方法与系统的现状,研究了基于热线法的新的数据处理手段,同时测算松散煤体导热系数及热扩散率,并设计开发了测试系统.利用交叉热线法测松散煤体导热系数,结合平行热线温升数据通过数值解法计算热扩散率.实验测试表明:导热系数与热扩散率测试结果可重复性好,最大偏差仅为0.726%,且与相关文献参照值相符. A new measurement method was developed, that could provide improved measurement of loose-coal thermal properties. The method was based on the hot-wire method and could determine thermal conductivity and diffusivity simultaneously. The bulk thermal conductivity was measured by cross-hot-wire method while the thermal diffusivity was calculated by numerical methods starting from thermal data taken parallel to the wire. The experiments show that the thermal conductivity and diffusivity measurements are reproducible and agree with the literature values. The maximum deviation only is 0. 726 %.
出处 《中国矿业大学学报》 EI CAS CSCD 北大核心 2009年第3期336-340,共5页 Journal of China University of Mining & Technology
基金 安徽省自然科学基金项目(050450404) 安徽省教育厅自然科学基金项目(KJ2008B189) 安徽省优秀青年基金重点项目(2008JQ1035ZD)
关键词 热线法 导热系数 热扩散率 松散煤体 hot-wired method thermal conductivity thermal diffusivity loose coal bulk