期刊文献+

电容层析成像技术在气固两相流检测中的应用 被引量:4

Application of Electrical Capacitance Tomography in Super Phase Pulverized-coal Transportation
下载PDF
导出
摘要 电容层析成像是一种对绝缘介质内部状态实现可视化的技术。文中介绍了一种应用于气固高压密相输送的小口径电容层析成像系统。电容传感器采用8电极结构,内径为10 mm,管道内压力达2 MPa.基于交流法的电容检测电路可以实现高分辨率测量,交流和直流两级增益可调可以实现宽范围电容检测。系统的成像速度达100帧/s. Electrical capacitance tomography (ECT) is the technology which can visualize the internal behavior of industrial process comprising dielectric components. An ac-based capacitance tomography, used in dense-phase transportation of gas ang solid with small-diameter pipe was introduced. The inside diameter of ECT pipeline sensor was 10 mm, the working pressure in pipe- line was 2 MPa. The ac-based capacitance measuring circuit has a high resolution. Wide range capacitance value can be measured by ac-based and dc-based programmable gain amplifier. It can collect tomographic image data at 100 frames per second.
出处 《仪表技术与传感器》 CSCD 北大核心 2009年第5期136-138,142,共4页 Instrument Technique and Sensor
关键词 电容测量 交流法 层析成像 capacitance measurement ac-based tomography
  • 相关文献

参考文献5

  • 1JAWORSKI A J, BOLTON G T. The design of an electrical capacitance tomography sensor for use with media of high dielectric permittivity. Measurement of science and technology, 2000 ( 11 ) :743 - 757.
  • 2YANG W Q, YORK T A. New AC-based capacitance tomography system. IEE Proc. -Sci. Meas. Technol, 1999, 146(1) : 47 -53.
  • 3王保良.电容层析成像技术及其在两相流参数检测中的应用.浙江大学,1998.
  • 4PENG L H, YANG W Q. Image reconstruction algorithms for electrical capacitance tomography . Measurement Science and Technology, 2003, 14(1): R1-R13.
  • 5王兴,颜华.工业过程电容层析成像系统的硬件设计[J].仪表技术与传感器,2001(11):35-37. 被引量:2

二级参考文献2

共引文献1

同被引文献29

  • 1田海军,周云龙.电容层析成像技术研究进展[J].化工自动化及仪表,2012,39(11):1387-1392. 被引量:10
  • 2牟昌华,彭黎辉,姚丹亚,萧德云.Image Reconstruction Using a Genetic Algorithm for Electrical Capacitance Tomography[J].Tsinghua Science and Technology,2005,10(5):587-592. 被引量:5
  • 3王妍,沙洪,任超世.医学电阻抗断层成像线电极与复合电极的仿真比较研究[J].中国生物医学工程学报,2006,25(5):637-640. 被引量:9
  • 4刘靖,姜凡,孙猛,刘石.非闭合电极电容层析成像传感器的设计及实验研究[J].传感技术学报,2007,20(9):1983-1986. 被引量:4
  • 5BECK M S,WILLIAMS R A. Process tomography; A European innova-tion and its applications. Measurement Science and Eechnology, 1996 ,7(3) :215 -224.
  • 6WARSITO W,FAN L S. Measurement of real-time flow structures ingas-liquid and gas-liquid-solid flow systems using electrical capaci-tance tomography ( ECT) ? Chemical Engineering Science, 2001, 56(21):6455 - 6462.
  • 7FASCHING G E,L0UDIN W J,SMITH N S. Capacitive system for 3-dimensional imaging of flnidized-bed density. Transactions on Instru-mentation and Measurement,1994,43(1) :56-62.
  • 8YORK T A,PHUA T N,REICHELT L,et al. A miniature electrical ca-pacitance tomography. Measurement Science & Technology, 2006, 15(8):2119 -2129.
  • 9JIANG F,LIUSH,WANG H G,et al. Application of electrical capaci-tance tomography on gas-solid two-phase flows in fluidized bed. 4thWorld Congress on Industrial Process Tomography, Aizu, Japan ,2005.
  • 10YANG W Q, Hardware design of electrical capacitance tomographysystems. Meas. Sci. Technol, 1996(7 ) :225 -232.

引证文献4