期刊文献+

600MW超超临界燃煤发电机组引风机选型分析 被引量:8

Type Selection of Induced-dralt Fan for 600MW Supercritical Coal-Fired Power Unit
下载PDF
导出
摘要 文章针对600 MW超超临界燃煤发电机组的引风机选型进行了研究,根据脱硫、脱硝系统的增加对锅炉风系统的要求,对是否单独设置增压风机提出了不同的配置方案,并对方案进行优选。讨论了不同类型风机的效率随负荷变化的特性,利用年费用最小法对不同方案的经济性进行分析比较,得出引风机与增压风机合并设置、选用静叶可调轴流式引风机方案最优的结论。 This paper discusses the type selection of induced-drah fan for 600 MW supercritical power unit. Different technical projects have been analyzed in order to fit the requirement of boiler gas & air system for gas desulphurization and denitrification. It analyzes efficiency change along with unit load, and economic analysis with least expense annually method. The project of variable static blade axial flow fan has been considered the best choice also with integration mode of booster fan and induced-drah fan.
出处 《湖北电力》 2009年第3期38-39,70,共3页 Hubei Electric Power
关键词 超超临界发电机组 引风机 增压风机 选型 经济性 supercritical power unit induced-dralt fan booster fan type selection economy
  • 相关文献

参考文献1

二级参考文献2

共引文献9

同被引文献38

  • 1邱朋华,刘辉,吴少华,孙绍增,杨龙滨,王国忠,刘栗.煤粉再燃对600MW锅炉NO_x排放的影响[J].工程热物理学报,2007,28(z2):149-152. 被引量:4
  • 2梁新磊,耿静,姚卫国.超临界600MW机组锅炉改造后引风机选型分析[J].热力发电,2013,42(4):102-103. 被引量:5
  • 3隋建才,徐明厚,丘纪华,朱文渊,高翔鹏,彭谷桃.煤粉燃烧过程中矿物质气化影响因素的模拟研究[J].中国电机工程学报,2005,25(14):78-83. 被引量:20
  • 4国家环境保护总局2008年第5号公告[Z].
  • 5山东电力工程咨询院有限公司.2x1000MW机组扩建工程勘察设计投标文件[Z].
  • 6毛建雄.从上海外高桥第三发电有限责任公司的经验看超超临界技术进一步发展的方向、瓶颈和解决方案[C].温州:600/1000MW超超临界机组技术交流2010年会论文集(上卷),2010,11.
  • 7秦曾煌.电工学(上册)[M].5版.北京:高等教育出版社,1998:289-290.
  • 8肖建平,王双童,沈玉兴,等.中国国电集团600MW火电机组节能降耗研究[R].南京:国电科学技术研究院,2012:56-57.
  • 9程海松,刘仕辉,尚雄英,等.国电铜陵发电有限公司#1、#2炉四台引风机变频改造项目后评价报告[R].铜陵:国电铜陵发电有限公司,2010,12.
  • 10徐永峰,刘家钰,郑金.国电双鸭山发电有限公司600MW机组脱硫增压风机、引风机二合一可行性研究报告[R].西安:西安热工研究院有限公司,2010,06.