期刊文献+

肾细胞癌患者栓塞前后CT灌注表现及其健侧体积变化 被引量:7

Perfusion Characteristics of Renal Tumor and Volume of Normal Kidney before and after Arterial Embolization on 64-slice Spiral CT
下载PDF
导出
摘要 目的应用64层螺旋CT研究肾细胞癌患者肾动脉栓塞前后灌注表现,以及健侧肾脏体积与血肌酐变化情况。方法对21例肾细胞癌患者患侧肾动脉栓塞前6~10d和栓塞后25~28h分别进行64层螺旋CT肾脏灌注扫描,测定栓塞前后肿瘤实质和健侧肾脏皮质的灌注参数,包括血流量、血容量和渗透性。比较栓塞前后肿瘤实质和健侧肾脏皮质的灌注参数变化,以及健侧肾脏体积与患者血肌酐变化。结果21例术后病理均为肾透明细胞癌。栓塞后较栓塞前患侧肾动脉肾细胞癌实质灌注参数显著下降,健侧肾皮质灌注参数显著升高,健侧肾脏体积显著增大(P<0.01),患者血肌酐水平差异无显著性(P>0.05)。结论肾脏灌注参数及体积变化反映了患肾动脉栓塞对健肾代偿功能的影响。多层螺旋CT灌注成像对肾脏病理生理功能的评价具有潜在的临床应用价值。 Objective To investigate the perfusion characteristics and compare the volume of normal kidney and serum creatinine (Scr) before and after arterial embolization on 64-slice spiral CT. Methods Totally 21 patients with renal tumor were enrolled. Sixty-four slice spiral CT was used for renal perfusion scan before and after patients underwent tumor arterial embolization. Perfusion characteristics, including blood flow, blood volume, and permeability of renal mass parenchyma and renal cortex in normal kidneys were calculated and the volume of normal kidneys was measured. The values of Scr in all patients were recorded. The perfusion characteristics, the volume of normal kidneys and the level of Scr before and after embolization were compared. Results Renal clear cell carcinoma was pathologically confirmed in all patients. After having supply blood arterial embolization of renal tumor, perfusion characteristics of tumor parenchyma significantly decreased, perfusion characteristics of renal cortex in normal kidney significantly increased, and the volume of normal kidneys was significantly enlarged (P 〈 0.01 ) ; however, the values of Ser in all patients were not significantly different ( P 〉 0.05 ). Conclusions The perfusion characteristics and volume of kidney may reflect the effects of renal arterial embolization on renal function. Perfusion imaging with multi-slice spiral CT is potentially useful in the evaluation of renal pathophysiologieal characteristics.
出处 《中国医学科学院学报》 CAS CSCD 北大核心 2009年第2期227-231,I0011,共6页 Acta Academiae Medicinae Sinicae
关键词 肾脏 肾肿瘤 CT 灌注成像 动脉栓塞 kidney renal tumor CT perfusion imaging arterial embolization
  • 相关文献

参考文献16

  • 1Robert JM, Barry B, Michael AC, et al. National comprehensive cancer network (NCCN) clinical practice guidelines in oncology: kidney cancer [EB/OL]. [2008-12-01] http ://www. nccn. org.
  • 2Park JH, Jeon SE, Kang HS, et al. Transcatheter renal arterial embolization with a mixture of ethanol and iodized oil [J]. Invest Radiol, 1986, 21(7) : 577-580.
  • 3Dawson P, Peters AM. Functional imaging in computed tomography: the use of contrast-enhanced computed tomography for the study of renal function and physiology [ J ]. Invest Radiol, 1993, 28 ( suppl 5 ) : s79-s84.
  • 4Miles KA, Hayball MP, Dixon AK. Functional imaging of changes in human intrarenal perfusion using quantitative dynamic computed tomography [ J]. Invest Radiol, 1994, 29 (10) : 911-914.
  • 5Lerman LO, Flickinger AL, Sheedy PF, et al. Reproducibility of human kidney perfusion and volume determination with electron beam computed tomography [J]. Invest Radiol, 1996, 31(4) : 204-210.
  • 6Probst P, Link L, Futterlieb A, et al. Experimental acute renal artery stenosis. Dynamic CT and renal perfusion [J]. Invest Radiol, 1984, 19(2) : 87-95.
  • 7Paul JF, Ugolini P, Sapoval M, et al. Unilateral renal artery stenosis: perfusion patterns with electron-beam dynamic CT- preliminary experience [ J]. Radiology, 2001, 221 ( 1 ) : 261-265.
  • 8Jaschke WR, Gould RG, Cogan MG, et al. Cine-CT measurement of cortical renal blood flow [J]. JCAT, 1987, 11 (5) : 779-784.
  • 9Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J]. BrJ Radiol, 1991,64(761) :409- 412.
  • 10Berne RM, Levy MN. Physiology [M]. 4th ed. St Louis: CV Mosby Co, 1998: 677-704.

二级参考文献57

  • 1许玉峰,唐光健.CT测量肾脏皮质厚度与年龄关系的研究[J].中华放射学杂志,2004,38(8):805-810. 被引量:26
  • 2袁庆中,田建明,王培军,邵成伟,李树平,李跃华,任方远.CT灌注成像在肾肿瘤鉴别诊断中的应用价值[J].中国医学影像技术,2005,21(3):436-439. 被引量:24
  • 3王刚,程雪,王志铭.肾脏CT灌注成像的研究进展[J].放射学实践,2006,21(8):860-862. 被引量:4
  • 4许楠,华佳,许建荣.不同分组肾透明细胞癌CT灌注成像的差异[J].临床放射学杂志,2007,26(6):571-574. 被引量:10
  • 5Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J]. Br J Radiol, 1991, 64 (761) : 409-412.
  • 6Blomley MJK, Coulden R, Bufkin C, et al. Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion [J]. Invest Radiol, 1993, 28(suppl 5) : s72-s77.
  • 7Dawson P, Peters AM. Functional imaging in computed tomography: the use of contrast-enhanced computed tomography for the study of renal function and physiology [ J ]. Invest Radiol, 1993, 28 (suppl 5) : s79-s84.
  • 8Miles KA, Hayball MP, Dixon AK. Functional imaging of changes in human intrarenal peffusion using quantitative dynamic computed tomography [ J]. Invest Radiol, 1994, 29 (10) : 911-914.
  • 9Lerman LO, Flickiuger AL, Sheedy PF, et al. Reproducibility of human kidney perfusion and volume determination with electron beam computed tomography [ J]. Invest Radiol, 1996, 31(4): 204-210.
  • 10Probst P, Link L, Futterlieb A, et al. Experimental acute renal artery stenosis. Dynamic CT and renal perfusion [ J ]. Invest RadM, 1984, 19(2) : 87-95.

共引文献48

同被引文献88

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部