期刊文献+

水力停留时间对聚乙烯醇膜生物反应器污水处理特性的影响 被引量:7

EFFECT OF HRT ON THE PERFORMANCE OF PVA MBR PROCESS TREATING DOMESTIC WASTEWATER
下载PDF
导出
摘要 通过考察不同水力停留时间(HRT)下NH4+-N和COD去除率的变化规律,确定了聚乙烯醇一体式膜生物反应器的最佳HRT为6h。在试验条件下,测得膜的临界通量约为14.0L·h-·1m-2,在次临界通量10.0L·h-1·m-2运行有利于系统长期稳定的运行,当膜通量为20.5L·h-1·m-2,大于膜的临界通量时,运行期间,过膜压差基本无稳定阶段,而是从开始运行便几乎呈直线性上升,表明发生不可逆污染现象。可见,为保证系统能够长期稳定运行,须操作在次临界通量以下。 The best hydraulic Retention Time (HRT) was 6h through investigating effect of HRT on NH4+-N and COD removal rate. The results showed that the critical flux was 14.0 L·h^-1·m^2, the system can run stable at 100 L·h^-1·m^2. The systems become unstable if the flux was more than critical flux which could lead to irreversible pollution.
出处 《水处理技术》 CAS CSCD 北大核心 2009年第7期88-91,共4页 Technology of Water Treatment
基金 国家自然科学基金项目(40572024)
关键词 聚乙烯醇膜 生物反应器 水力停留时间 膜污染 临界通量 PVA membrane membrane bioreactor hydraulic retention time(HRT) membrane fouling critical flux
  • 相关文献

参考文献5

二级参考文献10

  • 1REN N Q,CHEN Z B,WANG A J,et al.Removal of organic pollutants and analysis of MLSS-COD removal relationship at different HRTs in a submerged membrane bioreactor[J].International Biodeterioration & Biodegradation,2005,55:279-284.
  • 2DEFRANCE L,JAFFRIN M Y.Comparison between filtrations at fixed transmembrane pressure and fixed permeate flux:application to a membrane bioreactor used for wastewater treatment[J].Journal of Membrane Science,1999,152:203-210.
  • 3HUANG X,GUI P,QIAN Y.Performance of submerged membrane bioreactor for demestic wastewater treatment[J].Tsinghua Science and Technology,2000,5:237-240.
  • 4GU G W,HE Y L.Study and application of the membrane bioreactor in wastewater treatment[M].Beijing:China Chemistry Industry Press,2002.
  • 5SHIM J K,YOO I K,LEE Y M.Design and operation considerations for wastewater treatment of municipal wastewater[J].Water Research,2002,36:413-420.
  • 6国家环境保护总局《水和废水监测分析方法》编委会.水和废水监测分析方法[M].第3版.北京:中国环境科学出版社,1989.
  • 7AHN K H,SONG K G,CHO E,et al.Enhanced biological phosphorus and nitrogen removal using a sequencing anoxic/anaerobic membrane bioreactor(SAM)process[J].Desalination,2003,157:345-352.
  • 8ROSENBERGER S,KRUGER U,WITZIG R,et al.Performance of a bioreactor with submerged membranes for aerobic treatment of municipal wastewater[J].Water Research,2002,36:413-420.
  • 9张绍园,王菊思,姜兆春.膜生物反应器水力停留时间的确定及其影响因素分析[J].环境科学,1997,18(6):35-38. 被引量:20
  • 10封莉,张立秋,王宝贞.一体式膜生物反应器的HRT确定[J].中国给水排水,2002,18(11):62-64. 被引量:11

共引文献75

同被引文献81

引证文献7

二级引证文献28

相关作者