摘要
目的了解中心供应室无菌室环境卫生现状,探讨管理对策。方法调查2007-2008年中心供应室无菌室环境卫生学监测结果。结果空气和环境物品卫生学检测合格率为91.1%~97.2%,灭菌包质量检查合格率为99.2%~100.0%,无菌室温、湿度检查达标率分别为92.3%和88.8%。结论完善各项管理措施,严格无菌室消毒制度,专人负责,职责明确,重视可能导致污染的每一个环节,是保证无菌室环境质量的重要对策。
OBJECTIVE To study the situation of central supply department and discuss the management of it. METHODS The hygienic monitoring results of sterile room in central supply department from 2007 to 2008 were invectigated. RESULTS The hygienic eligible rate of air, environment and objects was 91.1-97.2 %. The qualified rate of sterilized packet was 99.2-100 %. The eligible rate of humidity and temperature in disinfection chamber was 92.3% and 88. 8%, respectively. CONCLUSIONS To consummate management measures and manage strictly sterilization procedure, assigning special person for the duty and attention to every details which easy tobe contaminated, all these measures mentioned above are the important countermeasures to quarantee environmental quality.
出处
《中华医院感染学杂志》
CAS
CSCD
北大核心
2009年第14期1857-1858,共2页
Chinese Journal of Nosocomiology
关键词
中心供应室
无菌室
环境质量
监测
管理对策
Central supply department
Sterile room
Environmental quality