摘要
建立水平管式降膜蒸发器蒸发换热的分布参数模型,考虑换热性能沿管子轴向、管排方向的变化,以及传热管发生干斑现象时对降膜蒸发的影响。对一降膜蒸发器的性能进行模拟分析,并考察管束布置、制冷剂液膜质量流量、管程布置以及满液位置对降膜蒸发器性能的影响。结果表明,计算结果和试验结果吻合良好,通过合理的设计管排方式和满液位置,可以减少或避免干斑现象的发生,提高降膜蒸发器性能。
A distributed parameter model is developed for predicting the performance of a horizontal-tube falling-film evaporator. In this model, the variation of heat transfer performance along the tube length and array, as well as the effect of the dry patch on the performance are considered. The model is applied to predicting the performance of a commercial falling film evaporator, and the influences of bundle layout, pass layout, refrigerant mass flow rate and the flooded level of refrigerant on the evaporator performances are studied. The results show that the simulation result agrees well with the experimental data, and it is possible to decrease or avoid the dry patch area on the tube bundle and therefore improve the evaporator performance by rationallly designing the layout of the tube bundle and the flooded level of the refrigerant.
出处
《机械工程学报》
EI
CAS
CSCD
北大核心
2009年第7期284-290,共7页
Journal of Mechanical Engineering
关键词
降膜蒸发器
干斑
分布参数模型
Falling film evaporator Dry patch Distributed parameter model