摘要
在胰岛素的效价测定方法中,以前一直用生物测定法。本文用HPLC法和小鼠血糖生物测定法进行了多批DNA重组人胰岛素(rh-Insulin)效价测定,结果表明两法间有良好的相关性,对高纯单组分rh-Insulin的效价测定,HPLC法可代替生物测定法。
RP-HPLC assay and mouse blood glucose bioassay were used for the determination of rh-insulin samples potencies.The results correlated well in two methods.The mouse blood glucose bioassay could be replaced by RP-HPLC assay for highly purified rh-insulin.
出处
《药物分析杂志》
CAS
CSCD
北大核心
1998年第4期241-243,共3页