期刊文献+

植入式无线颅内压自动监测系统 被引量:1

A Wireless Implantable System for Automatically Measuring Intracranial Pressure
下载PDF
导出
摘要 从临床应用出发,提出了一种新的颅内压监测系统方案——植入式无线颅内压自动监测。该系统基于现代传感器和微电子技术,由体外部分和植入体组成,两部分完全分离,通过射频信号传输能量和数据,并实现颅内压的自动监测。该系统使用方便、安全可靠,具有较高的测量精度。 To fulfil the clinical application, a new method of measuring Intracranial pressure ( ICP for short), which is described as a wireless implantable system for automatically measuring intracranial pressure, is brought up in this paper. It is based on modern sensor and micro - electronics. This system consists of implantable part and a part outside body. When the system operates, the two part mentioned above communicates with each other by radio frequency signal to realize the dynamic measure of ICP. It can be conveniently and safely used, and with it, we can reach a higher precision.
作者 陈昭祥 李平
出处 《微计算机应用》 2009年第8期69-72,共4页 Microcomputer Applications
关键词 植入式 无线 颅内压 LSK implantable, wireless, intracranial, pressure, LSK
  • 相关文献

参考文献5

二级参考文献16

  • 1Wilkinson HA. Intracranial pressure, In:Youmans JR,eds. Neurological Surgery [M].3 ed edition. Saunder Company. 1990. 661-695.
  • 2Cruz J. Head injury management in the United States[ J]. Crit Care Med, 1996,24(5) :897.
  • 3Narayan PK. Intracranial pressure and CT[J]. J Neurosurg,1994,81(6) :810.
  • 4Chan KH. The effect of changes in cerebral perfusion upon middle cerebral blood flow velocity and jugular bulb venous oxygen sataration after severe brain injury[ J]. J Neurosurg,1992,77(1) :55.
  • 5Kiening KL. Monitoring of cerebral oxyseneation in patients with severe head injuries: brain tissure PO2 versus jugular vein oxygen sataration[J]. J Neurosurg,1996,85(4) :751.
  • 6Santibrink HV. Continuous monitoring of partial pressure of brain tissue oxygen in patients with severe head injury[J]. Neurosury,1996,38(1) :21.
  • 7Magnano M. Impedance measurement as a non-invasive technique for monitoring of intracranial pressure variations[J]. Audiology, 1994,33(2) :237.
  • 8Schoser BG, Rimenschneider N, Hansen HC,et al. The impact of raised intracranial pressure on cerebral venous hemodynamic:a prospective venous trauscranial doppler ultrasonography study [ J ]. J Neurosurg. 1999.91 (5) ,744-749.
  • 9Czosnyka M,Smielewski P,Piechik S,et al. Hemodynamic charaterization of intracranial pressure plateau waves in head-injury patients[J].J Neurosurg, 1999,91( 1 ) : 11-19.
  • 10Wayenberg JL. Non-invasive measurement of intracranial pressure in neonates and intants: experience with the rotterdam teletranducer [ J]. Acta Ncurochir Suppl (wien), 1998,71 ( 1 ) :70-73.

共引文献52

同被引文献8

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部