期刊文献+

双近贴式X射线像增强器成像系统的三维噪音测量及其分析技术 被引量:2

3-D Noise Measurement and Analysis for a Double Proximity Focusing X-ray Image Intensifier Radiography Imaging System
下载PDF
导出
摘要 针对基于双近贴式X射线像增强器的射线成像系统,提出了该系统的三维噪音测试及分析方法.分析了各噪音因子的含义,用三维曲线描绘出空间域和时间域噪音的分布情况,结合数字图像处理技术,测量了双近贴式X射线像增强器成像系统在微焦斑射线源四种照射条件下的三维噪音,并对其结果进行分析.分析表明,其结果与双近贴式X射线像增强器成像系统实际性能相吻合. A double proximity focusing X-ray image intensifier radiography imaging system was made as an experimental object.A new method was used for measuring and analyzing 3-D noise of this system.By analyzing 3-D noise of this system,the distribution of noise both in time field and frequent field with curves of three dimentions was drawn.The 3-D noise of a double proximity focusing X-ray image intensifier radiography imaging system was measured and analyzed under four different conditions with the help of digital image processing technology.The result of measurement and analysis agrees well with the performance of the two side proximity of X-ray image intensifier radiography imaging system.
出处 《光子学报》 EI CAS CSCD 北大核心 2009年第8期1932-1936,共5页 Acta Photonica Sinica
基金 西安市科技创新支撑计划(ZH0713)资助
关键词 X射线像增强器 三维噪音 空间噪音 时间噪音 射线成像系统 X-ray image intensifier 3-D noise Spatial noise Temporal noise Radiography
  • 相关文献

参考文献7

二级参考文献12

  • 1Gerald C H. Testing and evaluation of infrared imaging systems[M]. Orlanddo Florida: SPIE Optical Engineers Press, 1998.
  • 2Dereniak E L, Boreman G D. Infrared detectors and systems[M]. New York: John Wiley&Sons Inc,1996.
  • 3D'Agostino J, Webb C. 3-D analysis framework and measurement methodology for imaging system noise[J]. SPIE, 1991,1488:110-121.
  • 4Scott L, Agostino D. Application of 3-D noise to MRTD prediction, appendix C of FLIR92 thermal imaging systems performance model[R]. [s.1.]: US Army Night Vision and Electronic Sensors Directorate, 1993.
  • 5Bai Lian'fa, Gu Guohua, Chen Qian, et al. 3-D test and analysis on time space SNR of low light level camera[J]. SPIE, 2000, 4223,178-182.
  • 6Jeffrey T B, Loos C G, Restaino R S, et al. High-QE-fast-readout wavefront sensor with analog phase reconstruction[J]. Proc SPIE, 1998, 3353: 972-982.
  • 7Gerald C H.Testing and evaluation of infrared imaging systems[M].Orlanddo,Florida:SPIE Optical Engineers Press,1998:156-189.
  • 8Dereniak E L,Boreman,G D.Infrared detectors and systems[M].NewYork:John Wiley & Sons,Inc,1996:46-52.
  • 9D'Agostino J,Webb C.3-D analysis framework and measurement methodology for imaging system noise[J].SPIE,1991,1488:110-121.
  • 10Scott L,D'Agostino J.Application of 3-D NOIse to MRTD prediction,appendix C of FLIR92 thermal imaging systems performance model[M].U.S.Army Night Vision & Electronic Sensors Directorate,1993:74-93.

共引文献22

同被引文献14

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部