随着上海崇明电网受电比率的不断增加,有必要选择合理的动态无功补偿装置来提高电网的电压稳定性。介绍了崇明电网的基本情况,分析了引起电网电压稳定性问题的原因,通过对两种无功补偿装置性能的比较,研究了崇明电网的动态无功补偿问题。
With the continuously growth of the power receiving ratio of Chongming network in Shanghai, it is necessary to select dynamic reactive power compensation device rationally to improve the voltage stability of the network. This paper introduces the basic situation of the Chongming network, analyzes the causes of the voltage stability problems in the network, researches the dynamic reactive power compensation issue of the Chongming network through the performance comparison of two reactive compensation devices.
出处
《供用电》
2009年第4期81-83,共3页
Distribution & Utilization
关键词
动态无功补偿
电压稳定
受电比率
dynamic reactive power compensation
voltage stability