摘要
本文首先讨论以混凝土保护层的性能推测砂浆保护层的耐久性是否可靠.然后介绍讨论100多个钢丝网水泥试件在荷载与氯化钠溶液(或酸性溶液)腐蚀共同作用下的长期性能实验结果;并结合工程实际,说明在保证质量前提下,保护层厚为5mm的镀锌焊接钢丝网水泥具有良好的耐久性.
An explanation shows that some predictions of durability of mortar cover by using behavior of concrete cover are not reliable. A longterm experimental study with more than 100 ferrocement specimen subjected to a joint action of loadNaCl or acidic solution has been performed. laboratory experimental results are integrated with field observations to demonstrate that good durability of welded mesh ferrocement can be obtained provided that quality of mortar cover with a thickness of 5mm is ensured.
出处
《水利学报》
EI
CSCD
北大核心
1998年第7期41-45,共5页
Journal of Hydraulic Engineering
关键词
镀锌焊接钢丝网
钢丝网水泥
厚度
保护层
耐久性
galvanized welded mesh, welded mesh ferrocement, cover thickness, cover quality, durability.