期刊文献+

应用新鲜全血对血液分析仪质控检测溯源性传递的评价 被引量:6

Evaluation of Transfer Traceability for Automated Hematology Analyzers with Fresh Whole Blood
下载PDF
导出
摘要 目的应用健康人新鲜全血溯源传递校准不同的血细胞分析仪,使不同的血细胞分析仪各参数之间具有可比性。方法用Sysmex XE-2100血细胞分析仪作为参比检测系统,对健康人新鲜全血进行白细胞、红细胞、血红蛋白、红细胞压积和血小板定值,再用该血对Sysmex XS-1000i血细胞分析仪进行校准;并对两台血细胞分析仪进行校准前和校准后的比对分析。结果校准前比对显示Sysmex XS-1000i血细胞分析仪的白细胞结果相对于Sysmex XE-2100偏差超出允许范围;校准后比对显示Sysmex XS-1000i血细胞分析仪各参数的偏差均在允许范围内。结论采用健康人新鲜全血溯源传递校准后,提高了不同血细胞分析仪之间检测结果的一致性。该方法用于实验室内部不同血细胞分析仪的溯源传递是有效、可行的。 Objective To calibrate hematology analyzers with healthy fresh blood to make their parameters comparable and traceable.Methods Hematology analyzer Sysmex XE-2100 was adopted as the reference system to measure fresh blood samples collected from healthy subjects.The detected results of white blood cell(WBC),red blood cell(RBC),hemoglobin(Hb),hematocrit(HCT) and platelet(PLT) were used to calibrate hematology analyzer Sysmex XS-1000i,and comparison studies were performed between two analyzers before and after calibration. Results Before Sysmex XS-1000i was call-brated, the deviation arising in WBC counting displayed on Sysmex XS-1000i was beyond the limits; after it was calibrated, the deviations of all the parameters shown on Sysmex XS-1000i were within the limits. Conclusions Parameters of hematology analyzers calibrated with fresh blood are comparable and traceable.
出处 《福建医科大学学报》 2009年第4期331-334,共4页 Journal of Fujian Medical University
关键词 血液化学分析 质量控制 血细胞计数 校准 blood chemical analysis quality control blood cell count calibration
  • 相关文献

参考文献9

  • 1王文娟,王佩佩,李雪芬,葛霞琴,童明,郭希超.新鲜血比对方法在血液分析仪室内质量控制中的应用[J].浙江大学学报(医学版),2008,37(1):88-92. 被引量:12
  • 2中华医学会检验分会血液学、体液学专家委员会.血液分析仪校准规范化的建议[A].见:丛玉隆.血液学体液学检验与临床释疑[M].北京:人民军医出版社,2004.294-298.
  • 3National Committee for Clinical Laboratory Standards.Method Comparison and Bias Estimation Using Patient Samples;Approved Guideline -Second Edition,NCCLS,EP9-A2.2002:1-49.
  • 4Gould N,Connell B,Dyer K,et al.Performance Evaluation of the Sysmex XE-2100TM,automated hematology analyzer[J].Sysmex J Int,1999,9:120-128.
  • 5Bull B S,Fujimoto K,Houwen B,et al.International Council for Standardization in Haematology.Recommendations for "Surrogate Reference" method for the packed cell volume[J].Lab Hematol,2003,9(1):1-9.
  • 6International Council for Standardization in Haematology.Expert panel on cytometry and international society of laboratory hematology task force on platelet counting:Platelet counting by RBC/Platelet ratio method[J].Am J Clin Pathol,2001,115(3):460-464.
  • 7冯仁丰,主编,临床检验质量管理技术基础[M].上海:上海科学技术文献出版社,2004.243.
  • 8高原,郑岚,杨剑敏,倪桂英,张泓.应用新鲜全血对多台血液分析仪比对的临床应用[J].检验医学,2008,23(3):295-297. 被引量:14
  • 9李德发,邓芳梅,祖莹.新鲜全血联合商业校准品在多台血细胞分析仪校准中的应用[J].临床输血与检验,2008,10(1):42-45. 被引量:9

二级参考文献17

  • 1彭黎明,邓瑞雪.血细胞自动分析校准的溯源[J].中华检验医学杂志,2005,28(5):475-477. 被引量:19
  • 2卫生部临床检验中心血细胞分析溯源专家组.建立血细胞分析溯源体系的有关问题[J].中华检验医学杂志,2006,29(4):381-381. 被引量:13
  • 3International Council for Standardization in Haematology. Prepared by the panel on cytometry : Reference method for the enumeration of erythrocytes and leucytes [J ]. Clin Lab Haemat,1994,16:131-138.
  • 4International Council for Standardization in Haematology. Expert panel on haemoglobi nometry: Recommendation for reference method for haemoglobinometry in human blood (ICSH satandard 1955 ) and specifications for international haemiglobincyanide standard [J]. J Clin Pathol, 1996,49: 271-274.
  • 5International Council for Standardization in Haematology. Prepared by expert panel on cytometry: Recommendation for reference method for packed cell volume (ICSH Satandard 2001) [J]. Lab Hematol,2001,7:148-170.
  • 6International Council for Standardization in Haematology. Expert panel on cytometry and international society of laboratory hematology task force on platelet counting.-Platelet counting by RBC/Platelet ratio method [J]. Am J Clin Pathol, 2001,115 : 460-464.
  • 7CONG Yu-long (丛玉隆). Clinical Laboratory and Perspective in Hematology and Osology (血液学体液学检验与临床释疑) [ M ].Beijing: People's Military Medical Press, 2004: 294-298.
  • 8National Committee for Clinical Labortory Standards. Method Comparison and Bias Estimation Using Patient Samples: Approved Guideline--Second Edition [ S ]. NCCLS document EP9-A2. Wayne ,PA :NCCLS, 2002,22 (19):21-22.
  • 9National Committee for Clinical Labortory Standards. Performance Goals for the Internal Quality Control of Multichannel Hematology Analyzers: Approved Standard [ S ]. NCCLS document H26-A. Wayne, PA : NCCLS, 1996,16 (12):4-5.
  • 10WANG Zhi-guo ( 王治国 ). Clinical Laboratory Quality Control Technology (临床检验质量控制技术)[M]. Beijing : People's Medical Publishing House, 2004 : 172-173 .

共引文献57

同被引文献37

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部