期刊文献+

青光眼诊断新技术需要临床应用评价 被引量:1

New technologies for glaucoma diagnosis require evaluation of their clinical application
原文传递
导出
摘要 海德堡视网膜断层扫描仪、相干光断层扫描仪及偏振光激光扫描仪等检测技术广泛应用于青光眼临床诊断已有多年,但其实用价值和临床意义尚缺少明确而规范的评判标准。每种检测仪器均需要进行诊断试验评价,而评价方法应当正确、规范而严谨,重在早期诊断和不同指标诊断性能的具体分析。诊断技术只有在临床应用与应用评价相结合时,才能获得真正的发展,并进而解决实际问题。 Optical coherence tomography (OCT), Heidelberg Retinal Tomography (HRT-Ⅱ ) and GDx have been used widely in glaucoma diagnosis for many years, but it is still uncertain in their practical value and clinical significance. Therefore, it requires an evaluation for the usefulness of each instrument in the diagnosis of glaucoma. The evaluation must be correct, standardized and strict in methodology, with emphasis on the early diagnosis and the concrete analysis of each parameter given by the different imaging instruments. Only if clinical application of these devices is combined with the practical evaluation, can these techniques make real progression and solve the clinical problems in the early diagnosis of primary open angle glaucoma.
作者 任泽钦
出处 《中华眼科杂志》 CAS CSCD 北大核心 2009年第10期868-870,共3页 Chinese Journal of Ophthalmology
关键词 体层摄影术 体层摄影术 光学相干 诊断技术 眼科 评价研究 青光眼 开角型 Tomography ophthalmological Evaluation studies Tomography, optical coherence Diagnostic techniques, Glaucoma, open-angle
  • 相关文献

参考文献18

  • 1Mardin CY, Junemann AG, The diagnostic value of optic nerve imaging in early glaucoma. Curt Opin Ophthalmol,2001,12 : 100- 104.
  • 2Mederios FA, Zangwill LM, Bowd C, et al. Comparison of the GDxVCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optic coherence tomograph for the detection of glaucoma. Arch Ophthalmol, 2004,122 : 827-837.
  • 3任泽钦,乔荣华,刘丽娜.HRT-Ⅱ指标体系的分析及其在正常眼压青光眼的应用[J].中国实用眼科杂志,2004,22(10):783-787. 被引量:9
  • 4Mederios FA, Zangwill LM, Bowd C, et al. Use of progressive glaucomatous optic disk changes as the reference standard for evaluation of diagnostic tests in glaucoma. Am J Ophthalmol, 2005,139 : 1010-1018.
  • 5Mederios FA, Zangwill LM, Bowd C, et al. Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. Invest Ophthalmol Vis Sci, 2006,47 : 1008-1015.
  • 6任泽钦,乔荣华,刘丽娜.正常眼压性青光眼中视盘分区指标改变与视野改变间的关系[J].中华眼科杂志,2006,42(3):204-208. 被引量:6
  • 7Johnson ZK, Siddiqui MA, Azuara-blanco A. The quality of reporting of diagnostic accuracy studies of optical coherence tomography in glaucoma. Ophthalmology,2007,114:213-219.
  • 8Zvia BE, Gadi W, Richard AB, et al. Glaucoma detection with Heidelberg retina tomograph 3. Ophthalmology, 2007, 114 : 466- 471.
  • 9Mederios FA,Vizzeri G,Zangwill LM. Comparison of retinal nerve fiber layer and optic disc imaging for diagnosing glaucoma in patients suspected of having the disease. Ophthalmology, 2008, 115 : 1340-1346.
  • 10朱丹,梁远波,段宣初,江冰.GDx VCCHRT—Ⅱ及Stratus OCT在青光眼诊断与随访中应用[J].中国实用眼科杂志,2008,26(6):532-535. 被引量:4

二级参考文献36

共引文献22

同被引文献2

引证文献1

二级引证文献1