以金陵大报恩寺琉璃新塔为例,介绍大型高层佛教建筑与现代高层民用建筑存在的明显区别,以我国现行的消防技术规范为指导,全面分析其在消防设计中可能存在的问题,结合工程特殊功能需求和结构形式,从总平面布局、建筑构造、防火分区、安全疏散、消防给水、防排烟、消防电气、内部装修设计等方面,探讨高层佛教建筑消防设计在实际中的应用。
Jinling Dabao'en Temple new Color-glazed Pagodo was taken as an example to introduce obvious difference between high-rise Buddhism building and modern high-rise civil construction. Guided by the current national fire codes, the questions which exist in the fire protection design were analyzed roundly. Finally, the application of square evacuation, fire fighting coverage, fire compartment, safe evacuation, fire elevator, fire water supply, smoke control , electrical equipment and interior trim in large-scale high-rise Buddhism buildings has been discussed.