目的 对比观察离子型76%泛影葡胺和非离子型300mgI/ml欧乃派克在X线造影检查中的副反应,讨论其机理及临床应用价值。材料与方法:观察305例,76%泛影葡胺组274例,欧乃派克组31例,造影剂用量20—60ml。结果:76%泛影葡胺组发生副反应14例(5.1%),欧乃派克组无一例副反应发生。结论:非离子型造影剂由于具有良好的理化特性,副反应明显低于离子型造影剂,因此在X线造影检查中,特别是高危人群应尽量使用非离子型造影剂。
purpose The adverse reaction of ion -type coutrastmedium - 76% Meglumine Diatrizoate and the nonion-type ?contrast medium -300 mg I/ml. Omnipaque were observed comparatively and the mechanism and the clinical application value were discussed ?Materials and methods 305 cases were studied;the 76% meglunine Diatrizoate group 274 cases,while the omnipaque group 31 cases,the volume of contrast medium was 20-60 ml. Results-. 14 cases got the advers erecation in Meglumine Diatrizoate group (5. 1%), while no cases got in omnipaque group ?Conclusions -. The adverse reactions rate of non - iou - type contrast mediumis greally lower than ion - type, So the non - ion - type contrast medium should be used as possible in x - ray contrast media examination. Particularly in allergy history and high-risk patients.