期刊文献+

光学相干层析术提取色散信息的初步研究 被引量:4

Dispersion Extraction with Optical Coherence Tomography:a Pilot Study
下载PDF
导出
摘要 为了提取生物组织的色散信息,提出了一种基于Fourier变换以及多项式拟合的方法.该方法通过对光学相干层析术的干涉包络进行Fourier变换,再将得到的相位谱进行多项式拟合以实现色散信息的提取.通过数值模拟及相关实验验证了该方法的可行性.本文的分析结果不但有助于实现动态的色散补偿,而且可以用于区分不同的生物组织,以及同一生物组织的不同生理状态. The dispersion signal in optical coherence tomography (OCT) carries the information about the structure and function of bio-tissues. In order to extract the information about the dispersion, a method based on the Fourier transform and the polynomial fit was presented. The interferogram envelope in OCT was Fourier transformed to the frequency domain, and then the second order dispersion information was obtained by performing a polynomial fit to the phase spectrum. Theoretical simulation and experimental data validated the method. The obtained results in this work not only could be used for the dynamical dispersion compensation, but also provide a way to characterize different tissues,and different physiological conditions.
作者 李鹏 高万荣
出处 《光子学报》 EI CAS CSCD 北大核心 2009年第10期2598-2602,共5页 Acta Photonica Sinica
基金 国家教育部博士点基金(200802880013) 江苏省自然科学基金(BK2008412) 江苏省六大人才项目基金(06-B-041) 江苏省高校青蓝工程基金 “江苏省‘333高层次人才培养工程’专项资助” 南京理工大学青年学者基金(Njust200302) 苏州大学重点实验室基金(KJS01002)等资助
关键词 医用光学与生物技术 光学相干层析成像 色散提取 FOURIER变换 二阶色散 Medical Fourier transforms optics and biotechnology Optical coherence tomography Dispersion extraction Second order dispersion
  • 相关文献

参考文献18

  • 1HUANG D, SWANSON E A, LIN C P, et al. Optical coherence tomography[J].Science, 1991,254(5035) : 1178- 1181.
  • 2FUJIMOTO J G. Optical coherence tomography for ultrahigh resolution in vivo imaging[J]. Nat Biotechnol, 2003,21 ( 11 ) : 1361-1367.
  • 3孟婕,丁志华,周琳.光学相干层析成像轴向超分辨研究[J].光子学报,2008,37(3):533-536. 被引量:11
  • 4HITZENBERGER C K, BAUMGARTNER A, FERCHER A F. Dispersion induced multiple signal peak splitting in partial coherence interferometry[J]. Optics Communications, 1998, 154(4): 179-185.
  • 5HITZENBERGER C K,BAUMGARTNER A,DREXLER W, et al. Dispersion effects in partial coherence interferometry: implications for intraocular ranging[J].Journal of Biomedical Optics, 1999,4( 1 ) :144-151.
  • 6WOJTKOWSKI M,SRINIVASAN V,KO T,et al. Ultrahigh- resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation[J]. Opt Express, 2004,12 ( 11 ) : 2404-2422.
  • 7MARKS D L, OLDENBURG A L, REYNOLDS J J, et al, Autofocus algorithm for dispersion eorreetion in optical coherence tomography[J]. Appl Opt, 2003, 42 (16) : 3038- 3046.
  • 8SMITH E D J, ZVYAGIN A V, SAMPSON D D. Real-time dispersion compensation in scanning interferometry[J]. Opt Lett ,2002,27(22) : 1998-2000.
  • 9XIE T, WANG Z, PAN Y. Dispersion compensation in high- speed optical coherence tomography by acousto-optie modulation[J]. Appl Opt ,2005,44(20) :4272 -4280.
  • 10李栋,丁志华,孟婕.双光栅快速扫描光学延迟线的色散补偿[J].光学学报,2007,27(3):505-509. 被引量:9

二级参考文献70

共引文献49

同被引文献36

  • 1Na Qin,Yana Liu,Lin Huang,Yi Xin,Xiao Zhang,Xiaoming Hu,Qin Li.Research on optical properties of cardiovascular tissues based on OCT data[J].Journal of Innovative Optical Health Sciences,2021,4(1):72-82. 被引量:2
  • 2HUANG D, SWANSON E A, LIN C P, et al. Optical coherencetomography[J]. Science, 1991, 254(5035): 1178- 1181.
  • 3TYCZYNSKI P, FERRANTE G, KUKREJA N, et al. Optical coherence tomography assessment of a new dedicated bifurcation stent[J]. Euro Intervention, 2009,5 ( 5 ) : 523-551.
  • 4BRANDENBURG R, HAILER B, HAUGER C. Real-time in vivo imaging of dental tissue by means of optical coherence tomography(OCT) [J].Optics Communications, 2003, 227(4- 6) :203-211.
  • 5GIANMARCO V, MADHUSUDHANAN B, CHRISTOPHER B, et al. Spectral domain-optical coherence tomography to detect localized retinal nerve fiber layer defects in glaucomatous eyes[J].Optics Express, 2009, 17(5) : 4004-4018.
  • 6MARCO R, GAVRIIL T, SHULIANG J, et aZ. Retinal tumor imaging and volume quantification in mouse model using spectral domain optical coherence tomography [J ]. Optics Eapress, 2009, 17(5) :4074-4083.
  • 7TUMI.INSON A R, POVAZAY B, HARIRI L P, et al. In vivo ultrahigh-resolution optical coherence tomography ofmouse colon with an achromatized endoscope[J]. Journal of Biomedical Optics, 2006, 11(6):064003.
  • 8SHARMA U, KANG J U. Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography[J]. The Review of Scientific Instruments, 2007, 78(11): 113102.
  • 9HAN J H, LIU X, SONG C G, et al. Common path optical coherence tomography with fiber bundle probe[J]. Electronics Letters, 2009, 45(22): 1110 - 1112.
  • 10TOSHIHIKO N, MASAHIRO W. Common-path double- pass optical interferometry using a wire-grid polarizer as a reference mirror[J]. Optical Review, 2008,15 (6) :276-279.

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部