导出
摘要 目的使用动态血糖监测系统观察老年2型糖尿病患者的黎明现象及盐酸二甲双胍治疗后黎明现象的改善状况。方法对6例临床判断有黎明现象的老年2型糖尿病患者佩戴实时动态血糖监测系统(GuardianR RTCGMS),给予盐酸二甲双胍治疗,观察黎明现象的改善情况。结果动态血糖监测显示6例患者均存在黎明现象,给予盐酸二甲双胍0.5g,2/d治疗,黎明现象得到明显改善,平均血糖水平从8.1±1.5mmol/L降至6.6±1.0mmol/L(P<0.01);日内平均血糖波动幅度从2.7±2.0mmol/L降至1.0±0.6mmol/L(P<0.01)。血糖≥8.0mmol/L所占的时间百分比由59.2%降至25.5%(P<0.05),3.9mmol/L<血糖<8.0mmol/L所占的时间百分比由39.7%增至73.2%(P<0.05)。结论盐酸二甲双胍可以有效地改善部分老年糖尿病患者的黎明现象,实时动态血糖监测有助于老年2型糖尿病患者黎明现象的诊断和治疗效果的观察。 Objective To observe early morning hyperglycaemia"dawn phenomenom"in type 2 elderly diabetes mellitus with Real-Time continuous glucose monitoring and assessment of curative effect by Metformin Hydrochloride. Methods Six type 2 elder diabetes patients with dawn phenomenom was measured by Guardian RT CGMS before Metformins Hydrochloride were taken, assessment of curative effect before and after Mefformin therapy. Results The dawn phenomenom were observed in patients by CGMS. Mefformin Hydrochloride,0.5g,twice a day were given and the dawn phenomenon were improved significantly. The mean blood glucose of the whole day were decreased from 8.1±1.5 mmol/L to 6.6±1.0 mmol/L(P〈0.05). The mean amplitude of glycemic fluctuation were decreased from 2.7+2.0 mmol/L to 1.0±0.6 mmol/L(P〈0.05). The percentage of TBG ≥8.0 mmol/L were reduced from 59.2% to 25.5%(P〈0.05). The percentage of 3.9 mmol/L〈TBG〈8.0 mmol/L were increased from 39.7% to 73.2%(P〈 0.05 ). Conclusions Mefformin Hydrochloride can effectively improve the "dawn phenomenom"in some type 2 elderly diabetes patients and the Guardian RT CGMS profile provides informations useful for the diagnosis of clawn phenomenom and assessment of curative effect.
出处 《中华保健医学杂志》 2009年第5期339-341,共3页 Chinese Journal of Health Care and Medicine
基金 保健专项基金科研课题(NO.解A064)
关键词 2型糖尿病 黎明现象 盐酸二甲双胍 实时动态血糖监测系统 Type 2 diabetes mellitus Dawn phenomenom Mefformin hydrochloride Guardian real-time continuous glucose monitoring system.
  • 相关文献

参考文献6

  • 1郑冬良.二甲双胍治疗黎明现象高血糖[J].浙江中西医结合杂志,2005,15(7):441-442. 被引量:1
  • 2徐岩,李春霖,田慧,李剑,成晓玲.实时动态血糖监测系统性能的临床评价[J].中华保健医学杂志,2008,10(5):343-346. 被引量:8
  • 3Battelino T,Phillip M ,Bolinder J,et al. Guardian ^R RT continuous glucose monitoring system with real time glucose values and alarm functions:A new tool for improving metabolic control in patients with T1DM.[J]. Pediatric Diabetes,2005, (Supp6) :3-4.
  • 4Carroll MF, Schade DS. The dawn phenomenon revisited:implications for diabetes therapy[J]. Endocr Pract,2005,11:55-64.
  • 5Garg S,Jovanovic L. Clinical thai of a seven-day continuous glucose sensor demonstrates the importance of fasting hyperglycemia and the dawn phenomenon [ J ]. Diabetes Care, 2007,29 : 2644 - 2649.
  • 6Reda E, Von Reitzenstein A, Dunn P, et al. Metabolic control with insulin pump therapy:the Waikato experience[J]. N Z Med J, 2007,120 : U2401.

二级参考文献7

  • 1[1]Klonoff,David C.FACP Continuous glucose monitoring technology.delivers detailed diabetes data[J].J Near-Patient Testing & Teehnol,2006,5:105-111.
  • 2[2]Battelino T,Phillip M,Bolinder J,et al.Guardian(R)RT continuous glucose monitoring system with real time glucose values and alarm functions:A new tool for improving metabolic control in patients with TIDM[J].Pediatr Diabetes,2005 (Supp 6):3-4.
  • 3[3]Macdonald AL,Judge S,Carrington A.The clinical accuracy of the Guardian RT during pregnancy in Type 1 diabetes:a case study[J].Diabetic Med,2006 (Suppl 23):275.
  • 4[4]Porter H,Lookinland S.Belfort MA.Evaluation of a new real-time blood continuous glucose monitoring system in pregnant women without gestational diabetes:A pilot study[J].J Perinat Neonatal Nurs,2004,18:93-102.
  • 5[5]Chee F,Femando T,van Heerden PV.Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS)in real time[J].IEEE Trans Inf Technol Biomed,2003,7:43-53.
  • 6[6]Clark WL,Anderson S,Farhy L,et al.Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucoseerror grid analysis[J].Diabetes Care,2005,28:2412-2417.
  • 7[7]Bode B,Gross K,Rikalo N,et al.Alarms based on real-time sensor glucose values alert patients to hypo-and hyperglycemia:the guardian continuous monitoring system[J].Diabetes Technol Ther,2004.6:105-113.

共引文献7

同被引文献1

  • 1陆再英,钟南山.内科学[M].7版.北京:人民卫生出版社,2010:282.