文章对目前常用的单侧输电线路故障阻抗测距算法进行了研究及仿真计算,揭示了算法间的内在联系,在此基础上给出了一种新的电力系统故障测距算法,仿真及实例计算证明了其正确性。
A deep going research on the commonly adopted fault location algorithms for high voltage transmission line using one terminal voltage and current is performed in this paper. The inner relationship of them is also analysed in detail, and on the basis of the analysis a new fault location algorithm is given. The correctness of this algorithm is proved by the result of simulation calculation and calculation based on a group of real testing data.
出处
《电网技术》
EI
CSCD
北大核心
1998年第11期15-17,26,共4页
Power System Technology