Non-invasive glucose measuring apparatus based on conservation of energy method 被引量:1

Non-invasive glucose measuring apparatus based on conservation of energy method
下载PDF
导出
摘要 A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardware and software of this apparatus were designed,and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism,and the relationship between convection,evaporation,radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method,using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other,and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A:100%,region B:0%). Accordingly,it is feasible to measure BGL with COEM. A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed, which can measure blood glucose level (BGL) frequently, conveniently and painlessly. The hardware and software of this apparatus were designed, and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism, and the relationship between convection, evaporation, radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method, using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other, and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A: 100%, region B: 0%). Accordingly, it is feasible to measure BGL with COEM.
出处 《Journal of Central South University》 SCIE EI CAS 2009年第6期982-986,共5页 中南大学学报(英文版)
基金 Project(07JJ6133) supported by the Natural Science Foundation of Hunan Province, China
关键词 节约能源法 血糖水平 测量仪 非侵入式 MSP430F149 全自动生化分析仪 能量守恒定律 基础 single chip non-invasive measurement blood glucose conservation of energy method
  • 相关文献

参考文献4

二级参考文献40

  • 1陈文亮,徐可欣,杜振辉,刘蓉,范世福.人体无创血糖检测技术[J].仪器仪表学报,2003,24(z1):258-261. 被引量:18
  • 2孙斐,孔德义,梅涛,陶永春.无创伤法测量血糖浓度的技术及其发展前景[J].生物医学工程学杂志,2005,22(1):171-174. 被引量:12
  • 3刘志宏.人体无创血糖检测方法的研究[J].中国科技信息,2006(02A):91-91. 被引量:4
  • 4Alavi SM,Gourzi M,Rouane A,et al.An original method for non-invasive glucose measurement:preliminary results.2001 proceedings of the 23rd Annual EMBS International Conference,Istanbul,Turkey,2001∶3318-3320
  • 5Blank TB,Ruchti TL,Lorenz AD,et al.Clinical results from a non-invasive blood glucose monitor.Photonics West 2002 Meeting,San Jose,CA,Jan,2002∶19-25
  • 6Stark E,Luchter K.Near-Infrared Analysis:A Technology for Quantitative and Qualitaitive Analysis.Applied Spectroscopy Review,1986;22(4)∶335
  • 7Frank I,Friedman J.A statistical view of some chemometrics regression tools.Technometrics,1993;35∶109
  • 8Stone M,Brooks R.Continuum regression:Cross-validated sequentially constructed prediction embracing ordinary least squares,partial least squares,and principal components regression.Journal of the Royal Statistical Society,Series B,1990;52(2)∶237
  • 9Omar S.Khall.Spectroscopic and clinical aspects of noninvasive glucose measurement.Clinical Chemistry,1999;45(2)∶165
  • 10Stephen FM,Timothy LR,Thomas BB,et al.Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy.Clinical Chemistry,1999;45(9)∶1651

共引文献30

同被引文献10

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部