凝结水精处理运行控制方式探讨 被引量:10

Discussion on Operation Control Mode of Condensate Polisher
下载PDF
导出
摘要 分析了氯离子对机组热力系统的影响,阐述了精处理混床运行状态与水汽品质的关系:即精处理混床出水随着氨的泄露,氯离子随之增加,并导致水汽系统氢电导率上升。提出凝结水精处理混床宜采用氢型方式运行,可有效控制氯离子的泄露,确保给水水质。 The influence on thermodynamic system by Cl- were analyzed, relationship between condensate polisher running and water & steam quality were expatited,i.e. Cl- in the effluent increased and cation conductivity of water & steam rised with leaking of ammonia from the condensated polisher. RH running mode of condensate polisher for super critical uints were recommended, leaked ammonia can be monitored by conductivity to judge the end point of the condensate polisher running, which can control leaking of Cl- and ensure feed water quality.
出处 《净水技术》 CAS 2009年第6期21-25,共5页 Water Purification Technology
关键词 氯离子 凝结水精处理 氢型运行 chloride ion condensate polisher RH running
  • 相关文献

参考文献5

  • 1David G Daniels.The TOC debate:between a rock and a hard pot [J]. Power,2002,146:55-63.
  • 2DL/T561-95,《火力发电厂水汽化学监督导则》,中华人民共和国电力行业标准[S].
  • 3GB/T12145-2008《火力发电机组及蒸汽动力设备水汽质量》,中华人民共和国国家标准[S].
  • 4DL/T805.1-2002《火电厂汽水化学导则第1部分直流锅炉给水加氧处理》,中华人民共和国电力行业标准[S].
  • 5DL/T912-2005《超临界火力发电机组水汽质量标准》,中华人民共和国电力行业标准[S].