期刊文献+

数字化变电站的GOOSE网络测试 被引量:26

Research on test technology of GOOSE network in digital substation
下载PDF
导出
摘要 对关乎数字化变电站网络化应用功能实现成败的GOOSE网络通信性能进行了分析,并按照某变电站的实际配置,搭建了模拟测试系统,提出了GOOSE网络在各种运行工况下的通信性能方面的测试方案,进行了对GOOSE接收、发送、集成等的测试,测试结果表明,GOOSE网络的性能可以满足应用要求,采用基于GOOSE通信机制的网络化应用功能实现方式技术上是可行的。 This paper analyzes GOOSE network communication performance which is very important in implementing application function based on network, designs a simulation system according to real configuration of a substation, and proposes the test scheme of communication performance of GOOSE network under different working conditions. Test result shows that GOOSE network performance can satisfy the request, the way of power system secondary application function implementation which is based on GOOSE communication mechanism is feasible.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2009年第24期85-89,93,共6页 Power System Protection and Control
关键词 IEC61 850 数字化变电站 GOOSE SNTP 网络性能测试 IEC61850 digital substation GOOSE SNTP test ofnetworkperformance
  • 相关文献

参考文献14

  • 1Dolezilek D J. Power System Automation[M]. Schweitzer Engineering Laboratories, Inc.
  • 2数字化电网关键技术研究框架-国家电网2007版[z].
  • 3Skeie T, Johannedden S, Brunner C. Ethernet in Substation Automation[J] . IEEE Control System Magazine, 2002, 22 (3). 43-51.
  • 4IEC 61850, Communication Networks and Systems in Substations[S].
  • 5魏勇.浅析全数字化变电站二次系统的全生命周期成本管理.电力系统保护与控制,2009,37(10).
  • 6殷志良,刘万顺,杨奇逊,秦应力.基于IEC 61850的通用变电站事件模型[J].电力系统自动化,2005,29(19):45-50. 被引量:72
  • 7刘永华,任歌武,张春峰,魏勇,李志超.数字化变电站过程层组网技术研究及应用[J].农村电气化,2008(S1):73-76. 被引量:3
  • 8国家电网科学技术进步奖申报书[Z].河南省电力公司,许继集团公司,2009.
  • 9张清枝,魏勇,赵成功.变电站网络化二次系统关键技术研究及应用[J].电力系统保护与控制,2009,37(8):47-52. 被引量:37
  • 10变电站网络化二次系统研究及应用技术报告[Z].河南省电力公司,许继集团公司,2008.