期刊文献+

64层螺旋CT超低剂量前门控轴面扫描在冠状动脉血管成像的应用 被引量:39

Low radiation dose coronary 64-slice spiral CT angiography using prospective electrocardiographtriggered scan
原文传递
导出
摘要 目的评价64层CT冠状动脉成像中前瞻性轴面扫描不同kV设置对射线剂量及图像质量的影响及临床应用价值,探讨〈1mSv冠状动脉检查的可行性。方法从拟行冠状动脉成像的患者中连续选取90例体质量指数(BMI)〈21.5kg/m2,且心率满足前瞻性门控轴面扫描条件的患者,平均心率(54±6)次/min(bpm)。90例患者数字表法随机分成A、B2组,A组45例扫描时管电压为100kV,B组45例扫描时管电压为120kV,根据患者BMI选择管电流,记录扫描中患者所受射线剂量,并对其图像质量进行评价(5分优,1分差)。采用配对t检验对2组的射线剂量和图像质量进行统计学分析。结果A组平均扫描剂量为(0.88±0.32)mSv,图像质量评分平均为(4.32±0.28)分;B组平均扫描剂量为(1.47±0.41)mSv,图像质量评分平均为(4.52±0.34)分。A、B组之间图像质量评分差异无统计学意义(t=0.771,P〉0.05):A组扫描剂量与B组相比较差异有统计学意义(t=12.125,P〈0.0t),平均减少40%。结论64层CT冠状动脉成像前瞻性轴面扫描中,对于BMI〈21.5kg/m2。的患者,可采用100kV管电压扫描,其辐射剂量可降到1mSv以下,并且其图像质量能满足临床诊断需要。 Objective To evaluate radiation dose and image quality of prospective electrocardiograph (ECG)-triggered coronary 64-slice CT angiography (CTA) with different kV, and the feasibility of coronary scan with 〈 1 mSv radiation dose. Methods Ninety consecutive patients[ heart rate: (54 ±6) bpm, BMI 〈 21.5 kg/m2 ] underwent 64-slice CTA using prospective ECG-triggered axial scan protocol. They were divided into two groups: 45 were in group A( 100 kV) , 45 were in group B( 120 kV) , and their electric currents were tailored to patient's BMI. The radiation dose was recorded and the image quality(5 fur excellent, 1 for bad)was blindly evaluated. Statistical t-test was performed between two groups on dose and image quality. Results The radiation dose of group A, B was ( 0. 88 ±0. 32 ) , ( 1.47 ±0. 41 ) mSv respectively. There was no significant difference between image quality of group A with 100 kV (4. 32±0. 28) and that of group B with 120 kV (4. 52 ±0. 34) (t =0. 771 ,P 〉0. 05). And radiation dose of the patient using axial scan protocol at 100 kV was decreased by 40% compared with that of group B at 120 kV(t = 12. 125, P 〈 0. 01 ). Conclusion Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure. For low-BMl ( 〈 21.5 kg/m2 ) patients, super low dose scan ( 〈 1 mSv) at 100 kV using prospective ECG-triggered axial scan could be selected. And the image quality can meet clinical diagnostic needs.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2009年第12期1255-1259,共5页 Chinese Journal of Radiology
关键词 体层摄影术 X线计算机 心脏 冠状血管 辐射剂量 Tomography, X-ray computed Heart Coronary vessels Radiation dosage
  • 相关文献

参考文献13

  • 1Hunold P, Vogt FM, Schmermund A, et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology,2003,226 : 145-152.
  • 2Trabold T, Buchgeister M, Kuttner A, et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo, 2003, 175: 1051-1055.
  • 3Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Call Cardiol, 2004, 43 : 1241-1247.
  • 4Leber AW, Becker A, Knez A, et al. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary, system : a comparative study using intravascular ultrasound. J Am Coil Cardiol, 2006, 47:672-677.
  • 5Mnllet NR, Cademartiri F, van Mieghem CA, et al. High- resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.Circulation, 2005, 112:2318-2323.
  • 6Raft GL, Gallagher MJ, O'Neill WW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol, 2005, 46:552-557.
  • 7Hsieh J, Londt J, Vass M, et al. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys, 2006, 33:4236-4248.
  • 8张森,杜湘珂,李剑颖.心电图调制电流对于容积CT心脏扫描图像质量及曝光剂量影响的评估[J].中华放射学杂志,2006,40(9):974-976. 被引量:45
  • 9高建华,戴汝平,郑静晨,王贵生,李剑颖,崔英,赵雯.应用后过滤重组降低64层螺旋CT心脏检查X线剂量的初步研究[J].中华放射学杂志,2007,41(10):1014-1018. 被引量:38
  • 10Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation, 2002, 106: 2051-2054.

二级参考文献23

共引文献92

同被引文献361

引证文献39

二级引证文献195

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部