期刊文献+

组织模拟液Intralipid-10%的吸收系数和各向异性因子的测量 被引量:2

Measurements of Absorption and Anisotropy Coefficients in Fat Emulsion Intralipid-10%
下载PDF
导出
摘要 用加吸收体法测量了组织模拟液Intralipid-10%的吸收系数和各向异性因子。运用漫射理论研究了点光源在无限大介质中的各向异性散射,实验结果得到(μa/D)~(1/2)的多个测量值的标准偏差小于0.6%,测量值与拟合值的残差方均根值为0.1%。标准偏差和残差的值表明了测量值的准确度。 The absorption and anisotropy coefficients of the fat emulsion Intralipid-10% were measured. An adding-absorber method was used for measurement of absorption and anisotropy coefficients of the Intralipid- 10%. Using the diffusion theory which has been extended to include anisotropy scattering for a point-source in infinite-medium geometry, the standard deviations of muhiple measurements for √μa/D are less than 0. 6% and the residuals between the measured data and the fits have rms values of O. 1%, where μa is the absorbing coefficient of the solution in our experiment and D is the diffusion coefficient of the medium. The values of the standard deviations and the residuals demonstrate the high precision of the measurements.
作者 张琳 张春平
出处 《发光学报》 EI CAS CSCD 北大核心 2009年第6期858-861,共4页 Chinese Journal of Luminescence
基金 国家自然科学基金(60578020)资助项目
关键词 吸收系数 各向异性因子 加吸收体法 absorption coefficient anisotropy coefficient an adding-absorber method
  • 相关文献

参考文献3

二级参考文献24

  • 1Pickering J W, Prahl S A, Van Wieringen N,et al. Double-integrating-sphere system for measuring the optical properties of tissue. Applied Optics, 1993,32(4):399-410
  • 2Kienle A, Lilge L, Patterson M S, et al. Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue. Applied Optics, 1996,35(13):2304~2314
  • 3Contini D, Martelli F,et al.Photon migration through a turbid slab described by a model based on diffusion approximation:I. Theory. Applied Optics, 1997,36(9): 4587-4599
  • 4Kienle A,Patterson M S.Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium.Journal of the Optical Society of America A, 1997,14(1):246~254
  • 5Groenhuis R A,et al. Scattering and absorption of turbid materials determined from reflection measurements:1. theory. Applied Optics, 1983,22(16):2456-2462
  • 6Farrell T J, Patterson M S,Wilson B C.A diffusion theory model of spatially-resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. Medical Physics, 1992, 19(4):879~888
  • 7Haskell R C, Svaasand L O, Tsay T T, et al. Boundary conditions for the diffusion equation in radiative transfer. JOSA A, 1994,11(10):2727-2741
  • 8Bolin F P, Preuss L E, Taylor R C,et al. Refractive index of some mammalian tissue using a fiber optic cladding method. Applied Optics, 1989,28(12):2297-2303
  • 9Tearney G J, Brezinski M E, Southern J F, et al. Determination of the refractive index of highly scattering human tissue by optical coherence tomography. Optics Letters, 1995,20(21):2258-2260
  • 10Hielscher A H, Jacques S L, Wang L, et al.The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissue. Physics in Medicine and Biology, 1995,40(11):1957~1975

共引文献27

同被引文献26

  • 1任芊,解国玲,董守龙,黄友之.OSC-PLS算法在近红外光谱定量分析中应用的研究[J].北京理工大学学报,2005,25(3):272-275. 被引量:9
  • 2LUWan-zhen(陆婉珍).Modern Near-Infrared Spectroscopy Analytical Technology (现代近红外光谱分析技术).Beijing:China Petrochemical Press(北京:中国石化出版社),2006.10.
  • 3Amerov A K,Chen J,Arnold M A.Applied Spectroscopy,2004,58(10):1195.
  • 4Wold S,Antti H,Lindgren F,et al.Chemometrics and Intelligent Laboratory Systems,1998,44:175.
  • 5Westerhuis J A,Jong S,Smilde A K.Chemometrics and Intelligent Laboratory Systems,2001,56:13.
  • 6HEISE H M,MARBCH R.Multivariate determination of blood substrates in human plasma by FTNIR spectroscopy[J].The International Society for Optical Engineering,1991,1575:507-508.
  • 7AMEROV A K,CHEN J,AMOLD M A.Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy[J].Analytical Chemistry,2005,77:4587-4594.
  • 8ALEXEEVA N V,ARNOLD M A.Impact of tissue heterogeneity on noninvasive near infrared glucose measurements in interstitial fluid of rat skin[J].Journal of Diabetes Science and Technology,2010,4 : 1041-1054.
  • 9YAMAKOSHI K,YAMAKOSHI Y.Pulse glucometry:a new approach for noninvasive blood glucose measurement using instantaneous differential nearinfrared spectrophotometry[J].Journal of Biomedical Optics,2006,11 (5):054028.
  • 10LORBER A.Error propagation and figures of merit for quantification by solving matrix equations[J].Analytical Chemistry,1986,58 : 1167-1172.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部