对双线电渣炉自耗电极“冻结”现象做了生产观察、实验,分析了“冻结”机理,找出了主要影响因素,提出“理想状态”重熔和“准理想状态”重熔措施,彻底克服了电极“冻结”问题,经两年多生产证明措施切实可行。
Observation and test to'frost'phenomenon of consumable electrode in double-line electroslag furnace were conducted,the mechanism of'frost'was analysed,the main active factors were found out,the remelting measures under'ideal state'and'quasi-ideal state'were proposed.In last two years all above works were proved effective and the'frost'was overcome.
出处
《河北冶金》
1998年第2期45-49,共5页
Hebei Metallurgy
关键词
双线
电渣炉
自耗电极
电极冻结
电渣重熔
double-line electroslag furnace consumable electrode frost mechanism