摘要 针对干熄焦余热锅炉过热器的特点,建立描述其内部传热的简化数学模型.应用该模型对一台86.6 t/h的干熄焦余热锅炉二级过热器烟气和蒸气温度分布进行模拟,模拟计算结果与实际运行过程具有较好的一致性.并进一步分析了过热器烟气进口温度和内部不同沾污情况对过热器换热的影响. In allusion to the characteristics of super-heater in coke drying quenching boiler(CDQ), simplified mathematical model was established to describe its internal heat transfer. Then the flue and steam's temperature secondary super-heater in a CDQ with 86.6 t/h loads were simulated. The calculation results show the agreement with the measured data, and the influences of super-heater inlet gas temperature and ifferent contamination on factors of heat transfer were analysed by using the model.
出处 《上海理工大学学报》 CAS 北大核心 2009年第6期529-534,共6页 Journal of University of Shanghai For Science and Technology
基金 国家"863"高科技研究发展计划资助项目(2006AA05Z219) 上海市科委重点攻关资助项目(071605127)
关键词 干熄焦余热锅炉 过热器 温度分布 传热系数 传热量 影响因素 coke drying quenching boiler super-heater temperature distribution coefficient of heat transfer heat transfer quantity influencing factors
  • 相关文献

参考文献17

二级参考文献36

  • 1初云涛,周怀春.基于炉内三维燃烧检测的蒸发系统分布参数建模[J].中国电机工程学报,2006,26(9):20-25. 被引量:8
  • 2初云涛,周怀春.蒸发系统分布参数特性动态仿真研究[J].中国电机工程学报,2006,26(11):17-22. 被引量:16
  • 3杨世铭.传热学[M].高等教育出版社,1987,10..
  • 4王孟浩.屏式过热器同屏热偏差的成因和计算方法[J].动力工程,1986,(6).
  • 5[1]周国义.舰用蒸汽锅炉[M].武汉:海军工程大学,2002.
  • 6[2]吉桂明.КВГЗ型增压锅炉技术说明书[R].哈尔滨:703研究所,1999.
  • 7[3]周国义.舰用锅炉原理[M].武汉:海军工程大学,2002.
  • 8[4]龚三省.舰用锅炉理论和管理[M].武汉:海军工程学院,1987.
  • 9[5]ЛебедевЮС, ПудровскийВВ. КорабельныеПаровыеКотлы [M]. Санкт-Петербург, 1997.
  • 10.锅炉机组热力计算标准方法[M].机械工业出版社,1973..