摘要
采用结晶法对金刚烷胺废水进行处理,以达到降低废水中金刚烷胺COD的目的。通过向水样中投加不同的反应药剂,确定使金刚烷胺结晶的最佳药剂种类及反应条件。研究结果表明:在pH值为3~10、反应温度为常温(23~25℃)的条件下投加Na2CO3,随着Na2CO3投量的不断增加COD的去除率不断增大,最大去除率可达到95%,处理效果良好。
In order to reduce COD of amantadine wastewater, amantadine wastewater was treated with the crystallization method. Reagents kinds and reaction conditions of treating amantadine wastewater were determined by experiment . The results show that when pH value is in the range of 3 - 10, Na2 CO3 is added at room temperature (23 - 25 ℃ ) , the removal rate of amantadine wastewater COD increases along with rise of NaECO3 dosage ,the maximum removal rate can reach to 95% ,the treatment effect of the method is very good.
出处
《辽宁化工》
CAS
2009年第12期861-862,共2页
Liaoning Chemical Industry
基金
辽宁省自然科学基金项目(20062004)
建设部科技攻关项目(05-K2-11)