摘要
分析了华电包头发电有限公司2×600MW燃煤机组凝结水系统存在的问题,解决了凝结水系统管道振动等问题,并取得了显著的节能效果,为类似机组凝结水泵变频改造提供了借鉴。
The problems existed in condensate system of 2×600 MW coal-fired units of Huadian Baotou Power Generation Corporation Limited were analyzed.The problems,such as pipe vibration of condensate system,were solved,and obvious energy-saving effect was obtained.The result can be used as reference for similar units in frequency conversion reformation.
出处
《华电技术》
CAS
2010年第1期41-42,68,共3页
HUADIAN TECHNOLOGY
关键词
凝结水泵
变频
除氧器水位
condensate pumps
frequency conversion
water level in deaerator