期刊文献+

分布式光纤测温技术在水工混凝土中的应用 被引量:7

Application of Distributed Optical Fiber Temperature Measurement System to Hydraulic Concrete
下载PDF
导出
摘要 基于分布式光纤测温技术的优势,针对其在大坝混凝土施工期测温过程中的要点,阐述了相应的布线、定位、铺设、保护、连接等工艺,并对光纤在线测温技术提出了改进建议。以金沙江溪洛渡水电站和大渡河深溪沟水电站成功应用实例证明,该法行之有效,准确可靠,为有效评估大坝安全提供了可靠依据。 Based on the advantages of distributed optical fiber temperature measurement technique and the key points of temperature measurement during the dam concrete construction, the corresponding techniques of routing, positioning, laying, protection, connection are represented. And improved suggestions of optical fiber real time temperature measurement technique are proposed. Take the process of temperature measurement in Xiluodu Hydropower Station on the Jinsha River and Sbenxigou Hydropower Station on the Dadu River for an example. The results show that the proposed method is effective, reliable and accurate. Thus, it provides basis for the dam safety assessment.
出处 《水电能源科学》 北大核心 2010年第2期106-108,68,共4页 Water Resources and Power
关键词 溪洛渡水电站 深溪沟水电站 分布式光纤 测温系统 布置 铺设 Xiluodu Hydropower Station Shenxigou Hydropower Station distributed optical fiber temperature measurement system arrangement laying
  • 相关文献

参考文献5

二级参考文献15

  • 1蔡顺德,望燕慧,蔡德所.DTS在三峡工程混凝土温度场监测中的应用[J].水利水电科技进展,2005,25(4):30-32. 被引量:9
  • 2刘天夫,张步新,陈阳,陈晓竹,张在宣.光纤后向拉曼散射的温度特性及其应用[J].中国激光,1995,22(9):695-700. 被引量:28
  • 3徐卫军,侯建国,李端有.分布式光纤测温系统在景洪电站大坝混凝土温度监测中的应用研究[J].水力发电学报,2007,26(1):97-101. 被引量:33
  • 4Measures R M, Alavie T, Maakant R et al. Bragg grating fiber optic sensing for bridge and other structure. Second European Conference on Smart Structures and Materials, Glagow, Scotland, 12-14, October, 1994d, SPIE, 1994D:162- 167.
  • 5Gusmeroli V, Martinelli M, Barberis A. Thermal expansion messurements of a concrete structure by embedded fiberoptic an effective example of simuhaeous strail-temperature detection, Second European Conference on Smart Structures and Materials. Giagow, Scotland, 12-14, October, 1994d, SPIE, 1994.D: 220-223.
  • 6M. Aufleger, Th. Strobl, J. Dornstadter. Fibre Optic Temperature Measurements for Dam Monitoring E C ]. International Conference on Health Monitoring of Civil Infrastructure Systems, 24- 26, October, 1994, Chongqing University Press, 121 - 128.
  • 7Hartoy H.A Distributed Temperature Semso Bused on Liguid-core Optical Fibers[J].IEEE J.Lightwave Technol,1983,LT-1(3):498~509.
  • 8Aufleger M, Strobl T H, Dornstadter J. Fibre Optic Temperature Measurements for Dam Monitoring[R].International Conference on Health Monitoring of Civil Infrastructure Systems,Chongqing:Chongqing University,1999.
  • 9赵仲刚.光纤通信与光纤传感[M].上海科学技术文献出版社.
  • 10蔡德所.光纤传感技术在大坝工程中的应用[M].水利电力出版社.