期刊文献+

基于双闭环模糊控制的有源电力滤波器 被引量:14

Double-closed-loop fuzzy controlled active power filter
下载PDF
导出
摘要 有源电力滤波器普遍采用双闭环控制。从双闭环协调控制的思路出发,通过对有源电力滤波器运行时内外环之间的相互耦合的研究,总结了双闭环PI参数协调控制的规律,并把总结的控制规律应用模糊控制的方式对有源电力滤波器进行控制。仿真结果和实验测试结果表明所述方法不仅使得直流母线电压在启动过程中的超调量很小,电压收敛速度快,而且发出的冲击电流很小,从而大大增强了系统运行的可靠性和直流母线电压的稳定性。仿真结果和实验测试结果表明,该方案能显著提高系统响应速度,并使注入电网的谐波电流达到IEEE519-1992的要求。 An active power filter(APF)is always controlled by double-closed-loop(DCL)regulation algorithm,namely,the inner current-loop and the outer voltage-loop.This paper studies the coordinates control of the inner current-loop and the outer voltage-loop of active power filter, and presents the rules of proportional-integral(PI)parameters tuning method in DCL. The active power filter is controlled by fuzzy logic controller whose fuzzification and defuzzification processes come from the coordinated selection of PI parameters in the inner current-loop and the outer voltage-loop controllers.The proposed control scheme results in smaller transient overshoot and faster convergence in the DC bus voltage of the APF.In addition,the compensating current generated by APF in start-up is very small.Therefore,system reliability as well as the stability of the DC bus voltage of the APF are greatly enhanced.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2010年第4期58-62,共5页 Power System Protection and Control
关键词 有源电力滤波器 协调控制 双闭环控制 模糊PI算法 智能控制 active power filter(APF) coordinated control double-closed-loop control fuzzy logic control intelligent control
  • 相关文献

参考文献8

二级参考文献28

  • 1马幼捷,周雪松,相伟.SVC综合非线性控制器在交直流混合系统中的应用[J].中国电机工程学报,2004,24(9):19-23. 被引量:21
  • 2杨君,王兆安,邱关源.并联型电力有源滤波器直流侧电压的控制[J].电力电子技术,1996,30(4):48-50. 被引量:69
  • 3王良,郝荣泰.三相不平衡有源无功和高次谐波补偿器控制系统的研究[J].电工技术学报,1996,11(4):31-35. 被引量:8
  • 4Inoue T,Iwai N S.High accuracy control of servomechanism for repeated contouring.Proceeding of the 10th Annual Symposium on incremental Motion Control System and Devices,Champaign,Illinios,USA:Incremental Motion Control Systems Society,1981,285~292
  • 5Chen C C,Hsu Y Y.A novel approach to the design of a shunt active filter for an unbalanced three-phase fore-wire system under nonsinusoidal conditions.IEEE Transactions on Power Delivery,2000,15(4):1258~1264
  • 6Akagi H.Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems.IEEE Trans on Power Delivery,1997,12(1):354~363
  • 7EI-Habrouk M,Darwish M K,P.Mehta.Active power filters:A review.IEE Proc-Electr Power Appl,2000,147(5):403~413
  • 8Mattavelli P,Marafao F.Repetitive-based control for selective harmonic compensation in active power filters.IEEE Trans on Industrial Electronics,2004,51(5):1018~1024
  • 9Zmood D N,Holmes D G.Stationary frame current regulation of PWM inverters with zero steady state error.IEEE Trans on Power Electronics,2003,18(3):814~ 822
  • 10Fukuda S,Yoda T.A novel current-tracking method for active filters based on a sinusoidal internal model.IEEE trans on Industry Applications,2001,37(3):888~895

共引文献87

同被引文献124

引证文献14

二级引证文献91