阐述了攀钢热电厂HDG150-59型给水泵存在的问题,平衡力校核及平衡盘系统烧损原因分析、改造方法及取得的效果。
Problems occurred in HDG150-59 water supply pump plant of the heat power plant of Panzhihua Iron & Steel Co. are described. Examination of a balance force and burn-out reasons of balance plate system, improvement methods and effects obtained are also presented.
出处
《冶金动力》
1998年第5期18-21,共4页
Metallurgical Power
关键词
给水泵
平衡盘
平衡力
锅炉
电厂
water supply pump, balance plate, balance force, excess amount