摘要
介绍了目前湿法烟气脱硫废水处理的几种方式,结合嘉兴电厂的实际情况,提出了废水排入渣系统的实验方案,并对实验数据进行了分析。在此基础上,探讨了烟气脱硫废水排入渣系统处理的可行性,分析了该方案存在的问题,并提出了相应的解决办法与建议。
This paper introduces several methods of wastewater treatment from FGD system, according to the instances of Jiaxing power plant, an experimental proposal is schemed, and the date from experiment is analyzed too. Based on the results of experiment, the feasibility of discharging wastewater from FGD system into ash-sluicing system is discussed, some problems resulted from the blending process is analyzed too, in view of these problems, some recommended resolutions are put forward.
出处
《浙江电力》
2010年第2期33-36,54,共5页
Zhejiang Electric Power
关键词
烟气脱硫
渣水系统
废水处理
腐蚀
FGD
ash-sluicing system
wastewater treatment
corrosion