厦门某医院采用水解酸化/接触氧化工艺处理污水,半年的实际运行结果表明,该工艺切实可行、运行成本低(0.28元/m3),出水水质稳定达到《医疗机构水污染物排放标准》(GB18466—2005)的一级标准。
The combined process of hydrolysis acidification and biological contact oxidation was used to treat the wastewater from a hospital in Xiamen City. The actual operation results for half year show that the combined process is feasible, and the operation cost is low, being 0.28 yuan/m^3. The effluent quality meets the first class criteria specified in Discharge Standard of Water Pollutants for Medical Organization ( GB 18466 - 2005 ).