期刊文献+

不同自锁托槽矫治系统在治疗早期引起上牙弓变化的研究 被引量:9

Changes of the maxillary arch produced by different self-ligating appliance systems during the leveling and aligning phases
下载PDF
导出
摘要 目的:分析比较用3种不同的自锁托槽矫治系统治疗后,在治疗的早期上牙弓的宽度和牙弓周长的变化。方法:选择3组轻度拥挤的病例,每组15人,分别使用Damon自锁托槽矫治系统、Smart-clip自锁托槽矫治系统、Tomy自锁托槽矫治系统进行治疗。结果:前磨牙间和尖牙间牙弓的宽度和牙弓周长均显著增加。牙弓周长的增加与治疗前的牙弓周长显著相关。牙弓长度无显著改变。结论:自锁托槽矫治系统在治疗的早期可以显著增加上牙弓的宽度和牙弓周长,各自锁托槽矫治系统之间无显著性差异。 Objective: To evaluate the changes in the transverse dimension and the perimeters of the maxillary archs produced by 3 self-ligating appliance systems during the leveling and aligning phases. Methods: 45 patients who had class I skeletal pattern and upper arch crowding 3 -6 mm were divided into 3 groups with 15 subjects in every group. The dental casts were analyzed. Results: Statisti- cally significant increases were recorded of all dentoalveolar widths (with the exception of intermolar width measured lingually) and arch perimeters. The increase in arch perimeter showed a significant negative relationship with the individual perimeter of the maxillary arch before treatment. No significant change was found in arch depth. Conclusion: The self-ligating appliance systems produce statistically signifieant increases in the transverse dentoalveolar width and the perimeter of the maxillary arch during the leveling and aligning phases of treatment.
作者 章利 骆英
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2010年第2期240-243,共4页 Journal of Practical Stomatology
关键词 自锁托槽矫治系统 牙弓周长 牙弓宽度 Self-ligating appliance Dental arch length Dental arch width
  • 相关文献

参考文献7

  • 1Damon DH.The Damon low-friction bracket:A biologically compatible straight-wire system[J].J Clin Orthod,1998,32(11):670-680.
  • 2Fortini A,Lupoli M,Cacciafesta V.A new low-friction ligation system[J].J Clin Orthod,2005,39(8):464-470.
  • 3Paquette DE,Beattie JR,Johnston LE Jr.A long-term compatison of nonextraction and pre-molar extraction edgewise therapy in "borderline" Class II patients[J].Am J Orthod Dentofacial Orthop,1992,102(1):1-14.
  • 4Kim E,Gianelly AA.Extraction vs nonextraction:Arch widths and smile esthetics[J].Angle Orthod,2003,73(4):354-358.
  • 5Bishara SE,Cummins DM.Treatment and posttreatment changes in patients with class II,division 1 malocclusion after extraction and nonextraction treatment[J].Am J Orthod Dentofacial Orthop,1997,111(1):18-27.
  • 6Baccetti T,Franchi L.Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance[J].Angle Orthod,2006,76(2):211-216.
  • 7Franchi L,Baccetti T.Forces released during alignment with a preadjusted appliance with different types of elastomeric ligatures[J].Am J Orthod Dentofacial Orthop,2006,129(5):687-690.

同被引文献89

引证文献9

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部