期刊文献+

基于声发射技术的蒸汽发生器传热管点腐蚀研究 被引量:1

Analysis Corrosion Dots of Steam Generator Tubes Based on Acoustic Emission Technique
下载PDF
导出
摘要 蒸汽发生器传热管的腐蚀是影响核动力装置安全运行的重要问题之一,传热管的腐蚀以点腐蚀的危害最为常见。利用声发射仪器,对蒸汽发生器传热管进行腐蚀实验时的信号进行采集和分析,并对腐蚀点进行了准确定位。实验结果表明,传热管的点腐蚀经历3个阶段:发展期、平稳期和迅速发展期。声发射技术能比其它任何无损检测方法更早地发现传热管腐蚀损伤,可对蒸汽发生器的安全和运行情况进行在线实时监测,具有重要的意义。 The corrosion inspection of steam generator tubes is an important problem which ensures the security of the nuclear plants.The most conventional corrosion of the tubes are corrosion dots.Based on the principle of acoustic emission technique,acoustic emission signals about tubes of steam generator gathered by instrument were analyzed,and the corrosion dots in the tubes were located accurately.The results show that corrosion dots of heat transfer tube are through three phases: Development period,stable period and rapid development period.Acoustic emission technique can be found earlier corrosion damage than any other non-destructive testing methods.The real-time inspection on the work of steam generator was achieved,according to which the corrosion dots can be judged timely.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2010年第3期315-319,共5页 Atomic Energy Science and Technology
关键词 蒸汽发生器 点腐蚀 声发射技术 steam generator corrosion dot acoustic emission technique
  • 相关文献

参考文献4

二级参考文献10

共引文献23

同被引文献12

  • 1l,iu Z, Genest M, Krys D. Processing thermography images for pitting corrosion quantification on small diameter duc- tile iron pipe [ J ]. NDT & E International, 2012,47 : 105 - 115.
  • 2He Y,Tian G,Zhang H,et al. Steel corrosion character- ization using pulsed eddy current systems [ J ]. Sensors Journal,IEEE,2012,12(6) :2113 -2120.
  • 3Kobayashi K,Banthia N. Corrosion detection in reinforced concrete using induction heating and infrared thennogra- phy[ J]. Journal of Civil Structural Health Monitoring, 2011,1(1 -2) :25 -35.
  • 4Baek S, Xue W, Feng M Q,et al. Nondestructive corrosion detection in RC through integrated heat induction and IR thermography[ J ]. Journal of Nondestructive Evaluation, 2012,31 (2) :181 - 190.
  • 5Yunze He, Gui Yun Tian, Li Xiang Chen, et al. Parame- ters influence in steel corrosion evaluation using PEC thermography[ C ]//Automation and computing ( ICAC ), 2011 17th international conference on IEEE, 2011: 255 - 260.
  • 6Gui Yun Tian, Yunze He, LiangCheng, Paul Jackson. Pulsed eddy current thermography fo corrosion character- ization[ C ]//International Journal of Applied Electromag- netics and Mechanics 2012, (39):269-276.
  • 7He Y,Tian G, Cheng L, et al. Corrosion characterisation under coating using pulsed eddy current thermography [ C ]//50th Annual Conference of The British Institute of Non-Destructive Testing,Telford, UK :2011.
  • 8Komorowski J P,Forsyth D S,Simpson D L,et al. Proba- bility Of Detection Of Corrosion In Aircraft Structures [ C ]//RTO AVT Workshop-Airframe Inspection Reliabil- ity under Field/Depot conditions, Brussels, Belgium, May 1998 and RTO MP, 1998,10.
  • 9Wally G, Oswald-Tranta B. The influence of crack shapes and geometries on the result of the thermo-inductive crack detection [ C ]. Proceedings of SPIE, the International Soci- ety for Optical Engineering. Society of Photo-Optical In- strumentation Engineers ,2007:654111.1 - 654111.8.
  • 10Yin A,Gao B, G Yun Tian, et al. Physical interpretation and separation of eddy current pulsed thermography [ J ]. Journal of Applied Physics,2013,113 (6) :064101 - 1 - 064101 - 8.