期刊文献+

一起微波天馈线故障的分析与处理 被引量:1

Analysis and treatment on antenna & feeder failure in a microwave link
下载PDF
导出
摘要 青台—南阳段微波通信电路传输电平较低,造成误码告警,严重时通信传输中断。为此,采用微波电测仪进行了现场测试分析,确认青台和南阳微波天线增益严重不足、青台馈线衰耗偏大是造成传输电平低的主要原因。青台和南阳的天馈线更换以后,传输电平恢复正常。 Because of low signal transmission level,error alarms and even breakdowns of transmission often occur at Qingtai—Nanyang microwave communication link.Analysis on the test results done by XPT-5/XPS-5 microwave electrical tester shows that the lack of antenna gain at both Qingtai and Nanyang,and bigger feeder lose in Qingtai are the main reasons.After the replacement of antenna and feeder at both sites,the transmission level returns to normal.
出处 《电力系统通信》 2010年第5期65-68,共4页 Telecommunications for Electric Power System
关键词 微波通信 微波天线 故障分析 microwave communication microwave antenna failure analysis
  • 相关文献

参考文献2

  • 1XFF-5/XPS-5微波电测仪使用说明书[Z].西安普天通信设备厂.2009.
  • 2数字微波通信设备说明书TRP-2/7/8/13 GHz,34MB-2500型[Z].NEC Corporation,1996.

同被引文献2

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部