期刊文献+

二维斑点追踪显像技术对腹主动脉瘤径向运动的初步研究

Preliminary assessment on the radial movement of abdominal aortic aneurysm by two-dimensional speckle tracking imaging
下载PDF
导出
摘要 目的通过应用二维斑点追踪显像技术(2DSTI)和定量分析软件对腹主动脉瘤(AAA)径向运动进行观测,与正常组进行比较,探讨该技术对腹主动脉瘤局部运动异常的研究价值。方法首先对30名正常人(正常组)腹主动脉分别采用M型超声和2DSTI进行前后壁位移测量。然后采用2DSTI对30名正常人、AAA患者(AAA组)21例进行管壁局部测量。采集3个心动周期的图像,进入Qlab脱机软件分析,取两组相应各节段各心动周期收缩期径向最大位移及舒张期径向最大速度的平均值。结果①正常组腹主动脉收缩期前、后壁位移M型超声测量与2DSTI测量结果相比无明显差别(P>0.05);②正常组收缩期最大径向位移前壁位移大于其余各壁(P<0.05),其余各壁之间比较无明显差异,舒张期最大径向速度各节段之间比较无明显差别(P>0.05);③AAA组各节段收缩期最大径向位移明显小于正常组(P<0.05),舒张期最大径向速度小于正常组各节段(P<0.05);④彩色多普勒显示正常组腹主动脉内呈现单一的红色层流,AAA组出现涡流及旋流,血流信号紊乱。结论 2DSTI可检测正常腹主动脉管壁及腹主动脉瘤壁径向运动,能够反映AAA局部各节段运动位移及速度的异常。 Objective By using two-dimensional speckle tracking imaging(2DSTI) and quantitative analysis software to observe abdominal aortic aneurysm(AAA) radial movement and compared the AAA group so as with the normal group to find the value of the technology on the study of AAA local abnormal motion.Methods Normal abdominal aorta anterior and posterior wall displacements of normal group were measured by M-mode ultrasonography and 2DSTI,then using 2DSTI for partial measurements of two groups;three cardiac cycle images and import them into Qlab off-line software were collected.Average values of systolic radial maximum displacement and diastolic radial maximum speed of the corresponding segment during three cardiac cycles were calculated.Results 1) normal abdominal aortic systolic anterior and posterior displacements measured by M-mode ultrasound and 2DSTI had no significant difference measurements(P 0.05);2) normal group systolic radial maximum displacements of the anterior segment were larger than the other segments(P0.05),the rest segments showed no significant difference between them(P0.05),diastolic maximum radial velocity of all segments showed no significant difference(P0.05);3) systolic radial maximum displacement of AAA group was smaller than that of the normal group of all segments(P 0.05) and diastolic maximum radial velocity was less than the normal group of all segments(P0.05).4) Color Doppler showed it was laminar flow in normal abdominal aorta and in AAA were swirling vortex flow.In AAA,the blood flow signal appeared disturbance.Conclusion 2DSTI can detect the radial movement of normal abdominal aorta and AAA to reflect the anomalies of AAA local segmental displacement and velocity.
出处 《实用医药杂志》 2010年第5期400-403,共4页 Practical Journal of Medicine & Pharmacy
关键词 斑点追踪 腹主动脉瘤 管壁运动 Speckle tracking Abdominal aortic aneurysm Wall motion
  • 相关文献

参考文献7

  • 1Ailawadi G,Eliason JL,Upchurch GR Jr.Current concepts in the pathogenesis of abdominal aortic aneurysm.J Vasc surg,2003,38(3):584-588.
  • 2叶红,范占明.腹主动脉瘤破裂的危险因素及影像学研究进展[J].中国介入影像与治疗学,2009,6(4):367-370. 被引量:12
  • 3Stian Langeland,Jan D'hooge,Patrick F.Wouters,et al.Experimental validation of a new ultrasound method for the simultaneous assessment of radial and longitudinal myocardial deformation independent of insonation angle.Circulation,2005,112(14):2157-2162.
  • 4马兰,吴卫华.二维斑点追踪技术在心血管疾病中的应用进展[J].中国心血管病研究,2008,6(6):472-474. 被引量:16
  • 5Basalyga DM,Simionescu Dr,Xiong W,et al.Elastin degradation and calcification in an abdominal aorta injury model:role of matrix metalloproteinases.Circulation,2004,110(22):3480-3487.
  • 6张龙方,姚克纯,汪娜,郭蕾,吴迪,邵波,刘淑萍.超声检测老年人真性腹主动脉瘤附壁血栓[J].中国介入影像与治疗学,2009,6(2):123-126. 被引量:7
  • 7Hope TA,Markl M,Wigstrom L,et al.Comparison of flow patterns in ascending aortic aneurysms and volunteers using fourdimensional magnetic resonance velocity mapping.J Magn Reson Imaging,2007,26(6):1471-1479.

二级参考文献24

  • 1梅志军,景在平,包俊敏,赵志青,刘崎,左长京,冯翔,赵珺,曲乐丰,陆清声.女性腹主动脉瘤的形态特点[J].第二军医大学学报,2004,25(8):869-871. 被引量:1
  • 2田民,赵卫,向述天,姜永能,罗罡,李莉媛,胡正琴.腔内隔绝术治疗腹主动脉瘤[J].中国介入影像与治疗学,2005,2(1):28-30. 被引量:3
  • 3Newman AB, Arnold AM, Burke GL, et al. Cardiovascular disease and mortality in older adults with small abdominal aortic aneurysms detected by ultrasonography: the cardiovascular health study. Ann Intern Med, 2001,134(3):182- 190.
  • 4Karkos CD, Mukhopadhyay U, Papakostas I, et al. Abdominal aortic aneurysm: the role of clinical examination and opportunistic detection. Eur J Vasc Endovasc Surg, 2000, 19(3) :299-303.
  • 5Conway KP, Byrne J, Townsend M, et al. Prognosis of patients turned down for conventional abdominal aortic aneurysm repair in the endovascular and sonographic era: Szilagyi revisited? J Vasc Surg, 2001,33(4) :752-757.
  • 6Finol EA, Keyhani K, Amo CH. The effect of asymmetry in abdominal aortic aneurysm under physiologically realistic pulsatile flow conditions. J Biomech Eng, 2003,125(2) :207-217.
  • 7Fillinger MF, Marra SP, Raghavan ML, et al. Prediction of rupture in abdominal aortic aneurysm during observation : Wall stress versus diameter. J Vasc Surg, 2003,37(4):724- 732.
  • 8Thubrikar MJ, Labrosse M, Robicsek F, et al. Mechanical properties of abdominal aortic ansuerysm wall. J Med Eng Technol, 2001,25(4) : 133-142.
  • 9Hallin A, Bergqvist D, Holmberg L. Literature review of surgical management of abdominal aortic aneurysm. Eur J Vase Endo vase Surg, 2001,22(3) : 197-204.
  • 10Brown PM, Zelt DT, Sobolev B. The risk of rupture in untreated aneurysms: the impact of size, gender, and expansion rate. J Vase Surg, 2003,37(2):280- 284.

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部