期刊文献+

基于变压器T形等效电路的漏电感参数特性分析 被引量:15

Analysis of the Leakage Inductance Parameter Characteristics Using the Transformer T-equivalent Circuit
下载PDF
导出
摘要 在对变压器T形等效电路电感参数的研究过程中,发现了漏电感参数在铁芯不同运行方式下的变化规律。利用基于有限元原理的电磁场专业仿真软件Maxwell 3D,对T形等效电路中漏电感参数在铁芯不同工作状态(不饱和与饱和)下的特性进行了仿真研究。结果表明:激励侧漏电感随饱和程度的加深,数值逐渐减小;感应侧漏电感随饱和程度的加深,数值逐渐增大;对于变压器总的漏电感而言,其数值与铁芯饱和程度无关,保持常数。通过采用有效主磁通的概念,重点着眼于变压器在不同工作状态下其等效匝数比发生变化这方面进行讨论研究,对仿真结果进行了定性分析并指明了其理论影响。 Characteristics of variation of the leakage inductance of a transformer are revealed through detailed analysis of the inductance of a transformer T-equivalent circuit.Using the finite element method based professional software,Maxwell 3D,the characteristics of inductances in several iron core states(saturated and unsaturated) are studied and some qualitative analysis are performed.The results show that the more serious the saturation of iron core is,the smaller the magnitude of leakage inductance at source side will be.The more serious the saturation of iron core is,the larger the magnitude of leakage inductance at load side will be.The leakage inductance of transformer as a whole,which remains constant,is not related to the status of transformer's iron core.In this paper,using the concept of valid main flux,equivalent turns ratio in several iron core states has been studied,the theoretical influence and qualitative analysis of simulation results has been done.
出处 《电力系统自动化》 EI CSCD 北大核心 2010年第11期38-42,112,共6页 Automation of Electric Power Systems
基金 国家自然科学基金资助项目(50907048) 高等学校博士学科点专项科研基金资助项目(20090201120018) 西安交通大学校内基金资助项目(08140002)~~
关键词 T形等效电路 漏电感 有效主磁通 等效匝数比 保护判据 transformer T-equivalent circuit leakage inductance valid main flux equivalent turns ratio protection criterion
  • 相关文献

参考文献9

二级参考文献66

共引文献231

同被引文献178

引证文献15

二级引证文献143

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部