摘要
将GO法用于核电厂电气主接线的可靠性分析,建立了核电厂典型3/2断路器主接线结构考虑有无检修状态(工作/失效/检修)的系统GO图并进行定性分析和定量计算。最后通过与故障树法所得结果的对比,验证了GO法在电气主接线可靠性分析领域的正确性和优势。
In this paper the GO method is used for analyzing the reliability of NPP bus system arrangement.Focusing on the typical one and a half breakers bus system,the detailed GO chart of typical work/failure(maintenance) two or three-state-component system is given,and the qualitative and quantitative analysis is conducted.Compared with the FTA results,the correctness and advantage of the GO methodology is verified.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2010年第3期69-73,77,共6页
Nuclear Power Engineering
关键词
可靠性
电气主接线
GO法
故障率
Reliability
Bus systems arrangements
GO methodology