期刊文献+

复杂性枢椎骨折合并相邻节段不稳的外科治疗 被引量:5

Surgical treatment of complicated atlas fracture combined with adjacent segment instability
原文传递
导出
摘要 目的 探讨复杂枢椎骨折合并相邻节段不稳的临床、影像学特点,提供合理的手术治疗策略.方法 回顾分析手术治疗且资料完整的21例枢椎骨折患者,男14例,女7例;平均年龄34岁.根据枢椎骨折的类型及其相邻寰枢关节、C2/3椎间的稳定情况,分别采用以下手术方式:(1)前路C2/3椎间盘切除及植骨、颈前路钢板固定;(2)齿状突螺钉固定;(3)后路C1~2椎弓根、颈椎侧块螺钉固定或联合前后路手术,稳定上颈椎.结果 21例全部获得6~36个月随访(平均12个月),术后佩戴颈围3个月,3个月均获得骨性融合,颈椎伸屈侧位片显示颈椎稳定,无内固定松动、脱出及断裂,无椎动脉损伤、神经损伤、脑脊液漏及切口感染等手术并发症.5例脊髓损伤神经功能恢复良好.结论 对于枢椎骨折,在确定骨折的类型及准确判断相邻寰枢关节、C2/3稳定性受破坏程度的基础上,通过手术治疗,可取得良好的疗效. Objective To study the clinical and radiographic characteristics of complicated axis fractures combined with adjacent segment instability and explore reasonable surgical treatment strategy. Methods A retrospective study was performed on 21 patients with axis fractures treated from August 2003 to June 2009. There were 14 males and 7 females at mean age of 34 years. The treatment strategy was based on the fracture type and the stabilities of adjacent atlantoaxial joint and intervertebral C2/3.Treatment strategies included anterior C2/3 interbody discectomy and fusion, anterior cervical plate internal fixation, odontoid screw fixation, posterior C1-2 pedicle screw fixation, cervical lateral mass screw fixation or combined anteroposterior approach. Results All patients were immobilized in a hard collar for thee months and followed up for 6-36 months (average 12 months), which showed bony fusion and cervical stability, with no intraoperative surgery-related complications such as loosening, extrusion or breakage of fixation, vertebral artery injury, nerve damage, cerebrospinal fluid leakage or wound infection. Neurological recovery was observed in five patients. Conclusions For complicated atlas fractures, correct identification of fracture type and instability disturbance of adjacent atlantoaxial joint and C2/3 as well as active treatment can conduce to better effect.
出处 《中华创伤杂志》 CAS CSCD 北大核心 2010年第6期523-527,共5页 Chinese Journal of Trauma
基金 上海市卫生局科研基金资助项目(2007032)
关键词 枢椎 脊柱骨折 骨折固定术 Axis Spinal fractures Fracture fixation, internal
  • 相关文献

参考文献13

  • 1贾连顺.枕颈部损伤诊断与治疗的基本概念[J].中华创伤杂志,2007,23(1):3-5. 被引量:12
  • 2Levine AM, Edwards CC. Treatment of injuries in the C1 - C2 complex. Orthop Clin North Am,1986, 17( 1 ) :31.
  • 3邱勇,钱邦平,王斌,俞扬,朱泽章.Hangman骨折的稳定性评价及疗效分析[J].中华创伤杂志,2007,23(1):12-15. 被引量:7
  • 4Verheggen R, Jansen J. Hangma's fracture: arguments in favor ofsurgical therapy for type Ⅱ and Ⅲ according to Edwards and Levine. Surg Neurol, 1998, 49(3) :253.
  • 5Guiot B, Fessler RG. Complex atlantoaxial fractures. J Neurosurg,1999, 91 Suppl 2:139 -143.
  • 6Ruth B. Pars screw fixation of a Hangman' s fracture: technical case report. Neurosurgery, 2005, 56 Suppl 1:204 - 208.
  • 7Pratt H, Davies E, King L. Traumatic injuries of the C1/2 complex: computed tomographic imaging appearances. Curr Probl Diagn Radiol, 2008, 37(1):26-38.
  • 8Graziano G, Jaggers C, Lee M, et al. A comparative study of fixation techniques for type Ⅱ fractures of the odontoid process. Spine,1993, 18(16) :2383 -2387.
  • 9Tuite GF, Papadopoulos SM, Sonntag VK. Casapar plate fixation forthe treatment of complex Hangman' s fractures. J Neurosurg,1992, 30(5) :761 -764.
  • 10Roy - Camille R, Saillant G, Mazl C. Internal fixation of the wnstable cervical spine by posterior osteosynthesis with plates and screw//Sherk HM, ed. The cervical spine. Philadelphia: Lippincott, 1989:390-403.

二级参考文献15

  • 1Doherty BJ. Heggeness MH, Esses SI. A biomechanieal study of odontoid fractures and fracture fixation. Spine, 1993,18 : 178 - 184.
  • 2Dickman CA. Foley KT, Sonntag VKH, et al. Cannulated screws for odontoid screw fixation and atlantoaxial transarticular screw fixation. J Neurosurg, 1995, 83 : 1095 - 1100.
  • 3Crob D, Dvorak J, Panjabi M, et al. Posterior occipitocervical fusion. A preliminary report of a new technique. Spine, 1991, 16 Suppl 3:17 -24.
  • 4Crob D, Cfiseo JJ rd. Parjabi MM, et al. Biomechanieal evaluation of four different posterior atlantoaxial fixation techniques. Spine,1992, 17:480 -490.
  • 5Richter M, Schmidt R, Claes L, et al. Posterior aflantoaxial fixation:biomechanical in vitro comparison of six different techniques. Spine,2002, 27 : 1724 - 1732.
  • 6Schneider RC, Livingston KE, Cave AI, et al. " Hangman' s fracture"of the cervical spine. J Neurosurg, 1965, 22:141 - 154.
  • 7Levine AM,Edwards CC.The management of traumatic spondylolisthesis of the axis.J Bone Joint Surg (Am),1985,67:217-226.
  • 8Wood-Jones F.The ideal lesion produced by judicial hanging.Lancet,1913,1:53.
  • 9Shea M,Wittenberg RH,Edwards WT,et al.In vitro hyperextension injuries in the human cadaveric cervical spine,J Orthop Res,1992,10:911-916.
  • 10Watanabe M,Nomura T,Toh E,et al.Residual neck pain after traumatic spondylolisthesis of the axis.J Spinal Disord Tech,2005,18:148-151.

共引文献15

同被引文献46

  • 1张沛,刘彬,陈望军,祝勇,马钢,曹振华,金淑霞.椎弓根技术在Hangman骨折中的应用[J].中国骨与关节损伤杂志,2005,20(2):112-113. 被引量:5
  • 2张红星,饶耀剑,朱文潇,等.寰枢关节失稳手术治疗的临床观察[J].中外健康文摘,2012,(43):5-6.
  • 3Bohlman H H.Current concepts review: treatment of fractures and dislocations of the thoracic and lumbar spine[J].J Bone Joint Sarg( Am ), 2005, 6 ( 7 ) : 165-166.
  • 4Chen Y, Guo Y, Chen D, et al.Diagnosis and surgery of ossification of posterior longitudinal ligament associated with dural ossification in the cervical spine[J].Eur Spine J, 2009, 18 (10) : 1541-1547.
  • 5Ivancic PC, Pearson AM, Tominaga Y, et al. Mechanism of cervical spinal cord injury during bilateral facet dislocation [J]. Spine (Phila Pa 1976), 2007,32 ( 22 ) : 2467 -2473.
  • 6LeeJY, Nassr A, Eck J C, et al. Controversies in the treatment of cervical spine dislocations [J]. Spine J, 2009,9(5) :418-423.
  • 7Nassr A, Lee JY, Dvorak MF, et al. Variations in surgical treatment of cervical facet dislocations [J]. Spine (Phila Pa 1976), 2008,33 (7):E188- E193.
  • 8Zhao L, Xu R, Liu J, et al. Comparison of two techniques for transarticular screw implantation in the subaxial cervical spine [J]. J Spinal Disord Tech, 2011,24(2) : 126-131.
  • 9谢宁,倪斌,陈德玉,叶晓健,肖建如,袁文.第2、3颈椎前路融合联合第2颈椎椎弓根固定治疗不稳定Hangman骨折[J].中华外科杂志,2008,46(4):267-269. 被引量:2
  • 10阮建伟,陈剑,范顺武.应用经关节螺钉固定在寰枢关节不稳中的生物力学研究与临床应用[J].中华骨科杂志,2008,28(9):759-763. 被引量:9

引证文献5

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部