摘要
简述了PHAST(Process Hazard Analysis Software Tool)软件中APIRP521计算模型计算火炬喷射火的要点,以某企业的液化天然气接收站火炬为例,详细说明了计算步骤,给出了计算结果,并作出简要分析。
This paper introduces jet fire of flame gas briefly using API 521 model in PHAST(Process Hazard Analysis Software Tool).With an example of one LNG receiver flame,it demonstrates calculation procedures in detail.It offers the results and carries out the analysis.
出处
《安全、健康和环境》
2010年第7期35-38,共4页
Safety Health & Environment