摘要
提出一种钢管混凝土柱与钢筋混凝土梁的新型节点形式。在钢筋混凝土梁与钢管混凝土柱连接区,钢管局部开矩形孔、节点区域钢管加强,使钢筋混凝土梁中的纵向钢筋直接伸入节点,节点混凝土与梁中混凝土成为整体,方便施工且保证节点刚度。通过对3个节点试件的试验,研究节点的破坏过程、破坏形态。研究结果表明,试件破坏是由梁和柱的破坏引起的,直至试件达到极限状态,节点尚未破坏,证实这种节点的可行性,且满足"强柱、弱梁、节点更强"的抗震设计原则。
A new type of concrete-filled steel tube (CFST) column-RC beam joint was presented in this paper. In the CFST column-RC beam connecting zone,the out steel tube of CFST column locally opened with rectangular hole and stiffened,the longitudinal reinforcing bars in RC beam stretched into the joint. The concrete was monolithically cast in the region of the beam,the column and the joint. The construction of joint was simplified and the joint stiffness was strengthened. The failure process and the failure mode of the specimens studied by experiments. The studies showed that the joint did not fail when the specimen was in limit state,while the beam and the column were damaged. The feasibility of the joint in the static load was proved. The joint meets the seismic design principles "strong column,weak beam,stronger joint".
出处
《工业建筑》
CSCD
北大核心
2010年第7期100-104,共5页
Industrial Construction
关键词
钢管混凝土
节点
试验研究
承载力
concrete filled steel tube
joint
experimental study
bearing capacity