一种声学造影剂声微显注射液中白蛋白微球的粒度分析 被引量:3

Particle analysis of air filled albumin microspheres of Shengweixian injection,an ultrasound contrast agent
下载PDF
导出
摘要 目的:测定心脏超声造影剂声微显注射液的白蛋白微球浓度和直径。方法:库尔特粒度分析仪小孔直径70μm,小孔电流800μA,增益系数2,操作方式为Siphon500μl。精密吸取样品,以9g·L-1NaCl溶液稀释至100ml,搅匀后立即测定。结果:测试杯中微球浓度在7.98×104~39.90×104ml-1时呈良好的线性关系;浓度测定的RSD为0.91%,直径测定的RSD为1.30%;测定准确度为99.5%。结论:用库尔特颗粒粒度分析仪测定声微显注射液的白蛋白微球,方法可靠,测定结果准确。 OBJECTIVES:To analyse air filled albumin microspheres of Shengweixian injection,an ultrasound contrast agent.METHODS:The parameters of the Coulter Multisizer was set that the orifice diameter was 70μm,the aperture current and gain were 800μA and 2 separately,and instrument control was siphon 500μl.Samples were diluted to 100ml with 9g·L -1 NaCl solution. RESULTS :It was linear over the range of 0.7~3.5×10 5ml -1 .The RSDs of the concentration and diameter analysis were 0.91% and 0.72% respectively. The average recovery was 99.5%.CONCLUSION:This method is proper,accurate and reliable for analyzing albumin microspheres of Shengweixian injection.
出处 《中国药学杂志》 EI CAS CSCD 北大核心 1999年第2期120-122,共3页 Chinese Pharmaceutical Journal
关键词 声微显注射液 声学造影剂 白蛋白微球 粒度 Shengweixian injection,ultrasound contrast agent,Coulter Multisizer,particle analysis