摘要
基于对合成绝缘子的结构、机械问题和电气问题的研究,对合成绝缘子在世界范围内输电线路上的挂网运行经验进行了分析,并提出合成绝缘子现阶段在高海拔、重冰区及特重冰区线路上暂不使用。
Based on the study of the structure, mechanical and electrical problems of the composite insulators, also based on the analysis of the operational experiences of composite insulators on the transmission line all over the world, this paper suggests that it is not suitable to make use on transmission lines on the high altitude, heary and very heavy icing areas.
出处
《中国电力》
CSCD
北大核心
1999年第2期60-62,共3页
Electric Power
关键词
合成绝缘子
性能研究
运行经验
composite insulator characteristic study operational experiences