期刊文献+

智能流量积算仪中的测温接口电路设计 被引量:3

The Design of the Interfacing Circuit for Temperature Measurement in intelligent Flow Totalizer
下载PDF
导出
摘要 在分析饱和蒸汽和过热蒸汽密度的数学模型的基础上指出,温度检测的偏差对智能流量积算仪的精度影响极大,尤其是饱和蒸汽,测温电路的精度应设计为远高于仪表的精度,同时引入一种基于比率法的高精度测温电路. Based on the analysis of the mathematics models of saturation steam density and superheat steam density the paper states that the deviation of the detection on temperature highly affects the accuracy of intelligent flow totalizer. Especially for saturation steam, the accuracy of the temperature detection circuit shall be designed higher than the accuracy of the instrument. Thus a temperature detection circuit based on ratio method with high accuracy is introduced.
作者 杨永竹
出处 《自动化仪表》 CAS 北大核心 1999年第2期38-42,45,共6页 Process Automation Instrumentation
关键词 流量积算仪 温度补偿 精度 智能仪表 Flow totalizer Temperature compensa-tion Temperature detection circuit Ac-curacy Ratio method
  • 相关文献

参考文献2

共引文献24

同被引文献3

  • 1许文海,杨明伟,朱炜,顾慧萍.基于FPGA技术的半导体激光器驱动电源的研制[J].红外与激光工程,2005,34(3):368-372. 被引量:18
  • 2FALQUIER D G. Erbium doped superfiuorescent fiber sources for the fiber optic gyroscope [ D ]. Ann Arbor : Bell & Howell Information and Learning Company, 2001.
  • 3HALL D C, BURNS W K, MOELLER R P. High-stability Er3 + - doped superfluorescent fiber sources [ J ]. Journal of Lightwave Technology, 1995, 13 (7) : 1452 - 1460